1-2. SELECTING THE INSTALLATION LOCATION
Note:
When operating the air conditioner in low outside temperature, be sure to follow the
instructions described below.
• Never install the outdoor unit in a place where its air inlet/outlet side may be exposed
directly to wind.
• To prevent exposure to wind, install the outdoor unit with its air inlet side facing the
wall.
7RSUHYHQWH[SRVXUHWRZLQGLWLVUHFRPPHQGHGWRLQVWDOODEDIÀHERDUGRQWKHDLU
outlet side of the outdoor unit.
Avoid the following places for installation where air conditioner trouble is liable to occur.
:KHUHÀDPPDEOHJDVFRXOGOHDN
• Where there is much machine oil.
:KHUHRLOLVVSODVKHGRUZKHUHWKHDUHDLV¿OOHGZLWKRLO\VPRNHVXFKDVFRRNLQJ
areas and factories, in which the properties of plastic could be changed and dam-
aged).
• Salty places such as the seaside.
:KHUHVXO¿GHJDVLVJHQHUDWHGVXFKDVKRWVSULQJVHZDJHZDVWHZDWHU
• Where there is high-frequency or wireless equipment.
• Where there is emission of high levels of VOCs, including phthalate compounds,
formaldehyde, etc., which may cause chemical cracking.
• The appliance shall be stored so as to prevent mechanical damage from occurring.
:KHUHDLUÀRZLVQRWEORFNHG
• Where cool (or warm) air spreads over the entire room.
• Rigid wall without vibration.
• Where it is not exposed to direct sunshine. Do not expose to direct sunshine also
during the period following unpacking to before use.
• Where easily drained.
• At a distance 1 m or more away from your TV and radio. Operation of the air condi-
WLRQHUPD\LQWHUIHUHZLWKUDGLRRU79UHFHSWLRQ$QDPSOL¿HUPD\EHUHTXLUHGIRUWKH
affected device.
,QDSODFHDVIDUDZD\DVSRVVLEOHIURPÀXRUHVFHQWDQGLQFDQGHVFHQWOLJKWV,QRUGHU
to make the infrared remote control operate the air conditioner normally. The heat
from the lights may cause deformation or the ultraviolet may cause deterioration.
:KHUHWKHDLU¿OWHUFDQEHUHPRYHGDQGUHSODFHGHDVLO\
• Where it is away from the other heat or steam source.
• Please ensure that the Router supports the WPA2-AES encryption setting before
commencement of the installation of this indoor unit equipped with the Wi-Fi interface.
• The End user should read and accept the terms and conditions of the Wi-Fi service before
commencement of the installation of this indoor unit equipped with the Wi-Fi interface.
• This indoor unit equipped with the Wi-Fi interface should not be installed and connected
to any Mitsubishi Electric system which is to provide application critical cooling or heating.
REMOTE CONTROLLER
• Where it is easy to operate and easily visible.
• Where children cannot touch it.
6HOHFWDSRVLWLRQDERXWPDERYHWKHÀRRUDQGFKHFNWKDWVLJQDOVIURPWKHUHPRWH
controller are surely received by the indoor unit from that position (‘beep’ or ‘beep
beep’ receiving tone sounds).
Note:
,QURRPVZKHUHLQYHUWHUW\SHÀXRUHVFHQWODPSVDUHXVHGWKHVLJQDOIURPWKHZLUHOHVV
remote controller may not be received.
OUTDOOR UNIT
• Where it is not exposed to strong wind. If the outdoor unit is exposed to a wind during
defrosting, the defrosting time will be longer.
:KHUHDLUÀRZLVJRRGDQGGXVWOHVV
• Where rain or direct sunlight can be avoided as much as possible.
• Where neighbours are not annoyed by operation sound or hot (or cool) air.
• Where rigid wall or support is available to prevent the increase of operation sound or
vibration.
• Where there is no risk of combustible gas leakage.
• When installing the unit at a high level, be sure to secure the unit legs.
• Where it is at least 3 m away from the antenna of TV set or radio. Operation of the
air conditioner may interfere with radio or TV reception in areas where reception is
ZHDN$QDPSOL¿HUPD\EHUHTXLUHGIRUWKHDIIHFWHGGHYLFH
,QVWDOOWKHXQLWKRUL]RQWDOO\
• Please install it in an area not affected by snowfall or blowing snow. In areas with
KHDY\VQRZSOHDVHLQVWDOODFDQRS\DSHGHVWDODQGRUVRPHEDIÀHERDUGV
Note:
It is advisable to make a piping loop near outdoor unit so as to reduce vibration
transmitted from there.
WARNING
7KHXQLWVKRXOGEHLQVWDOOHGLQURRPVZKLFKKDYHWKHÀRRUVSDFHVSHFL¿HG
below.
LN50VG2: 2.5 m²
LN50VGHZ/60VG: 3.9 m²
When the indoor unit is connected to the multi type outdoor unit of R32
UHIULJHUDQWSOHDVHFRQVXOW\RXUGHDOHUDERXWWKHÀRRUVSDFHVSHFL¿HG
As for the details, please refer to the Installation Service Manual for New
Refrigerant System.
INDOOR UNIT
*1 Connect to the power switch which has a gap of 3 mm or more when open to interrupt the source power phase. (When the
power switch is shut off, it must interrupt all phases.)
*2 Use wires in conformity with design 60245 IEC 57.
1HYHUXVHSLSHVZLWKWKLFNQHVVOHVVWKDQVSHFL¿HG7KHSUHVVXUHUHVLVWDQFHZLOOEHLQVXI¿FLHQW
*4 Use a copper pipe or a copper-alloy seamless pipe.
*5 Be careful not to crush or bend the pipe during pipe bending.
*6 Refrigerant pipe bending radius must be 100 mm or more.
*7 If pipe length exceeds B m, additional refrigerant (R32) charge is required. (No additional charge is required for pipe leng
th
less than B m.)
Additional refrigerant = A × (pipe length (m) - B)
,QVXODWLRQPHDWUHVLVWLQJIRDPSODVWLFVSHFL¿FJUDYLW\
%HVXUHWRXVHWKHLQVXODWLRQRIVSHFL¿HGWKLFNQHVV([FHVVLYHWKLFNQHVVPD\FDXVHLQFRUUHFWLQVWDOODWLRQRIWKHLQGRRUXQLW
DQGLQVXI¿FLHQWWKLFNQHVVPD\FDXVHGHZGULSSDJH
CAUTION
(Could lead to serious injury in particular environments when operated incorrectly.)
■
Install an earth leakage breaker depending on the
installation place.
If an earth leakage breaker is not installed, it could cause
electric shock.
■
Perform the drainage/piping work securely ac-
cording to the installation manual.
If there is defect in the drainage/piping work, water could
drop from the unit, soaking and damaging household
goods.
■
'RQRWWRXFKWKHDLULQOHWRUWKHDOXPLQXP¿QVRI
the outdoor unit.
This could cause injury.
■
Do not install the outdoor unit where small ani-
mals may live.
If small animals enter and touch the electric parts inside
the unit, it could cause a malfunction, smoke emission,
RU¿UH$OVRDGYLVHXVHUWRNHHSWKHDUHDDURXQGWKH
unit clean.
■
Do not operate the air conditioner during interior
FRQVWUXFWLRQDQG¿QLVKLQJZRUNRUZKLOHZD[LQJ
WKHÀRRU
Before operating the air conditioner, ventilate the room
well after such work is performed. Otherwise, it may
cause volatile elements to adhere inside the air condi-
tioner, resulting in water leakage or scattering of dew.
■
To prevent damage from static electricity, touch
a nearby metal body to discharge static electric-
ity from yourself before touching the indoor unit
equipped with the Wi-Fi interface.
Static electricity from the human body may damage the
Wi-Fi interface unit.
■
Do not use the indoor unit equipped with the
Wi-Fi interface nearby other wireless devices,
microwaves, cordless phones, or facsimiles.
It can cause malfunctions.
1-3. SPECIFICATIONS
Model
Power supply *1
:LUHVSHFL¿FDWLRQV
3LSHVL]H
(thickness *3, *4)
Maximum amount of
refrigerant charge *7
Indoor unit
Outdoor unit
Rated Voltage
Frequency
Breaker
capacity
Power supply *2
Indoor/outdoor
connecting wire *2
Gas / Liquid
MSZ-LN18VG2
-
230 V
+]
-
-
4-core
1.0 mm²
ø9.52 / 6.35 mm
(0.8 mm)
-
MUZ-LN25VG2
10 A
3-core
1.0 mm²
1000 g
MUZ-LN25VGHZ2
1050 g
MSZ-LN35VG2
MUZ-LN35VG2
MUZ-LN35VGHZ2
12 A
3-core
1.5 mm²
MSZ-LN50VG2
MUZ-LN50VG2
16 A
3-core
2.0 mm²
1550 g
MUZ-LN50VGHZ
1910 g
MSZ-LN60VG2
MUZ-LN60VG
ø12.7 / 6.35 mm
(0.8 mm)
(LN25, 35/50/50HZ, 60)
Pipe length and height difference
Max. pipe length
20/30/30 m
Max. height difference
12/12/15 m
Max. number of bends *5, *6
10
Refrigerant adjustment A *7
20 g/m
No additional charge length B *7
10/15/7 m
Insulation thickness *8, *9
8 mm