2-4. PIPE FORMING AND DRAIN PIPING

Pipe Forming

•  Place the drain hose below the refrigerant piping.
•  Make sure that the drain hose is not heaved or snaked.
•  Do not pull the hose when applying the tape.
•  When the drain hose passes the room, be sure to wrap insula-

tion material (obtainable at a store) around it.

2-1. FIXING OF INSTALLATION PLATE

‡ )LQGDVWUXFWXUDOPDWHULDOVXFKDVDVWXGLQWKHZDOODQG¿[LQVWDOODWLRQSODWHKRUL]RQ

-

WDOO\E\WLJKWHQLQJWKH¿[LQJVFUHZV¿UPO\

‡ 7RSUHYHQWLQVWDOODWLRQSODWHIURPYLEUDWLQJEHVXUHWRLQVWDOOWKH¿[LQJVFUHZVLQWKH

KROHVLQGLFDWHGLQWKHLOOXVWUDWLRQ)RUDGGHGVXSSRUW¿[LQJVFUHZVPD\DOVREHLQVWDOOHG

in other holes.

•  When the knockout is removed, apply vinyl tape to the knockout edges to prevent damag-

ing the wires.

‡ :KHQEROWVUHFHVVHGLQWKHFRQFUHWHZDOODUHWREHXWLOL]HGVHFXUHLQVWDOODWLRQSODWH

using 11 × 20 · 11 × 26 oval hole (450 mm pitch).

•  If the recessed bolt is too long, change it for a shorter one available in the market.

2-2. WALL HOLE DRILLING

1) Determine the wall hole position.
2) Drill  a  ø65  mm  hole.  The  outdoor  side  should  be  5  to 

7  mm lower than the indoor side.

3) Insert wall hole sleeve (C).

2-3. CONNECTING WIRES FOR INDOOR UNIT

You can connect indoor/outdoor lead wire without removing the front panel.

1) Open the front panel.
2) Remove VA clamp.
3)  Pass indoor/outdoor unit connecting wire (A)  from the back of the indoor unit and process 

the end of the wire.

/RRVHQWHUPLQDOVFUHZDQGFRQQHFW¿UVWWKHHDUWKZLUHWKHQLQGRRURXWGRRUXQLWFRQ

-

necting wire (A) to the terminal block. Be careful not to make mis-wiring. Fix the wire to 

the terminal block securely so that no part of its core is appeared, and no external force 
is conveyed to the connecting section of the terminal block. 

5) Firmly tighten the terminal screws to prevent them from loosening. After tightening, pull 

WKHZLUHVOLJKWO\WRFRQ¿UPWKDWWKH\GRQRWPRYH

6) Secure indoor/outdoor unit connecting wire (A) and the earth wire with the VA clamp. 

Never fail to hook the left claw of the VA clamp. Attach the VA clamp securely.

2.  INDOOR UNIT INSTALLATION

Rear, right, or downward piping

1) Put the refrigerant piping and the drain hose together, then 

¿UPO\DSSO\SLSLQJWDSH*IURPWKHHQG

2) Insert the piping and the drain hose into the wall hole sleeve 

(C), and hook the upper part of the indoor unit on the instal-

lation plate (1).

3) Check if the indoor unit is hooked securely on the installation plate (1) by moving the 

unit to left and right.

4) Thrust the lower part of the indoor unit into the installation plate (1).

Drain Piping

•  If the extension drain hose has to pass through a room, be sure to wrap it with commer-

cially sold insulation. 

‡ 7KHGUDLQKRVHVKRXOGSRLQWGRZQZDUGIRUHDV\GUDLQÀRZ)LJ

•  If the drain hose provided with the indoor unit is too short, connect it with drain hose (I) 

that should be provided at your site. (Fig. 2)

•  When connecting the drain hose to the hard vinyl chloride pipe, be sure to insert it securely 

into the pipe. (Fig. 3)

Do not make drain piping as shown below.

Do not raise

Accumulated 
drain water

Air

Waving

Water 
leakage

Water 
leakage

Water 
leakage

Tip of drain 
hose dipped 
in water

Ditch

At least 
50 mm 
gap

Downward 

slope

Drain 

hose

Soft hose 

I.D. 15 mm

Drain hose

Hard vinyl chloride 

pipe I.D. 30 mm

Insert 
securely

Different 

diameter joint

70 cm 
or more

Fig. 1

Fig. 2

Fig. 3

•  For  future  servicing,  give  extra  length  to 

the connecting wires.

•  Make earth wire a little longer than others. 

(More than 60 mm)

•  Do not fold the excess wire, or cram it into 

small space. Take caution not to damage 
the wires.

•  Be sure to attach each screw to its corre-

spondent terminal when securing the cord 
and/or the wire to the terminal block.

Note:

 Do not place the wires between the 

indoor unit and the installation plate (1). 

Damaged wire could cause heat genera-

WLRQRU¿UH

Wall

Outdoor 
side

ø65 mm

5-7 mm

Installation plate (1)

Center of 
ø65 mm hole

111

 mm 

or more

101

 mm 

or more 

60

 mm or more/

150

 mm or more for left/left rear 

piping (using spacer)

Ceiling

Wall

Wall

Fixing 
screw (2)

100 mm

Level 

* Same for left hole.

Lead wire

15 mm

35 mm

Fixing screw

VA clamp

Indoor/outdoor unit 
connecting wire (A)

Indoor terminal block

Indoor/outdoor 
unit connecting 
wire (A)

Outdoor terminal block

Earth wire 
(green/yellow)

S1 S2 S3

S1 S2 S3

Felt tape (4)

Piping tape (G)

Cut off in case of 
left piping.

Drain cap

Drain cap

Drain hose

Drain cap

Drain hose

Fig. 1

Fig. 2

Fig. 3

Fig. 4

Fig. 5

1) Put the refrigerant piping and the drain hose together, 

WKHQ¿UPO\DSSO\IHOWWDSHIURPWKHHQG

 

Felt tape (4) overlap width should be 1/3 the tape width. 
Use a bandage stopper at the end of felt tape (4).

2) Pull out the drain cap at the rear right of the indoor unit. 

(Fig. 1)

•  Hold the convex section at the end and pull the drain 

cap.

3) Pull out the drain hose at the rear left of the indoor unit. 

(Fig. 2)

•  Hold the claw marked by the arrows and pull out the 

drain hose forward.

4)  Put the drain cap into the section to which the drain hose 

is to be attached at the rear of the indoor unit. (Fig. 3)

•  Insert not sharp-edged tools such as screwdrivers into 

the hole at the end of the cap and insert the cap fully 
into the drain pan.

5) Insert the drain hose fully into the drain pan at the rear 

right of the indoor unit. (Fig. 4)

•  Check if the hose is hooked securely to the projection 

of its inserting part at the drain pan.

6) Insert the drain hose into wall hole sleeve (C), and hook 

the upper part of indoor unit on installation plate (1). 
Then, move the indoor unit completely to the left in order 
to make placing the piping in the back space of the unit 
easier.

7) Cut out a piece of cardboard from the shipping box, roll 

it up, hook it onto the back rib, and use it as a spacer to 
lift the indoor unit. (Fig. 5)

8) Connect the refrigerant piping with the extension pipe 

(B).

9)  Thrust the lower part of the indoor unit into the installation 

plate (1).

Left or left-rear piping
Note:

Be  sure  to  reattach  the  drain  hose 

and the drain cap in case of left or 

left-rear piping.

Otherwise, it could cause drops of 
water to drip down from the drain 
hose.

Liquid pipe

Gas pipe

Felt tape (4) 

Indoor/outdoor unit 
connecting wire (A)

Piping tape (G)

Insert the 
scale. *

Align the 
scale with 
the line. *

Содержание MSZ-LN18VG2

Страница 1: ...F VKRFN WKH unit falling etc When plugging the power supply plug into the outlet make sure that there is no dust clogging or loose parts in both the outlet and the plug Make sure that the power supply plug is pushed com pletely into the outlet If there is dust clogging or loose parts on the power supply plug or the outlet it could cause electric shock or UH I ORRVH SDUWV DUH IRXQG RQ WKH SRZHU VXS...

Страница 2: ... QVWDOO WKH XQLW KRUL RQWDOO Please install it in an area not affected by snowfall or blowing snow In areas with KHDY VQRZ SOHDVH LQVWDOO D FDQRS D SHGHVWDO DQG RU VRPH EDIÀH ERDUGV Note It is advisable to make a piping loop near outdoor unit so as to reduce vibration transmitted from there WARNING 7KH XQLW VKRXOG EH LQVWDOOHG LQ URRPV ZKLFK KDYH WKH ÀRRU VSDFH VSHFL HG below LN50VG2 2 5 m LN50VGH...

Страница 3: ...QVWDOODWLRQ SODWH LQJ VFUHZ 4 25 mm 5 3 Wireless remote controller 1 4 Felt tape For left or left rear piping 1 5 Corner box R 4 6 Corner box L 4 7 Battery AAA for 3 2 8 LU FOHDQLQJ OWHU 1 9 Air purifying device 1 Outdoor unit 10 Drain socket VG type only 1 Air inlet LN25 35 50 50HZ 60 LN25 35 50 50HZ 60 3 When any 2 sides of left right and rear of unit are clear 4 The manufacturing year and month...

Страница 4: ...drain piping as shown below Do not raise Accumulated drain water Air Waving Water leakage Water leakage Water leakage Tip of drain hose dipped in water Ditch At least 50 mm gap Downward slope Drain hose Soft hose I D 15 mm Drain hose Hard vinyl chloride pipe I D 30 mm Insert securely Different diameter joint 70 cm or more Fig 1 Fig 2 Fig 3 For future servicing give extra length to the connecting w...

Страница 5: ...1 part about 90 degrees around the hinge point you have just created to put the parts together 3 Press the base of portion with the mark to snap into place When changing the part disassemble by moving the part in a reverse direction The parts that were not used may be necessary in the future if the air conditioner is relocated so ask customers to keep those parts 4 Attach the assembled corner box ...

Страница 6: ...t any scratches Flare nut Die Fig 5 Fig 6 3 OUTDOOR UNIT INSTALLATION Copper pipe Wing nut type WARNING When installing the unit securely connect the refrigerant pipes before starting the compressor 3 1 CONNECTING WIRES FOR OUTDOOR UNIT 1 Open the service panel 2 Loosen terminal screw and connect indoor outdoor unit connecting wire A from the indoor unit correctly on the terminal block Be careful ...

Страница 7: ...art operation automatically when power supply is resumed To the user After installing the unit make sure to explain the user about auto restart function If auto restart function is unnecessary it can be deactivated Consult the service representative to deactivate the function Refer to the service manual for details 4 PURGING PROCEDURES LEAK TEST AND TEST RUN Pressure gauge for R32 R410A Emergency ...

Страница 8: ...river deeply into the holes 2 Pry off the right and left arm holders by moving the screwdriver down and towards the back wall 3 Remove the safety string from the upper center of the panel assembly Installation procedure 1 Install the panel assembly following the removal procedure in reverse 2 Be sure to press the positions as indicated by the arrows in order to attach the assembly completely to th...