background image

En-

 AUTO mode (Auto change over)

The unit selects the operation mode according to the difference between the 

room temperature and the set temperature. During AUTO mode, the unit 

changes mode (COOL↔HEAT) when the room temperature is 2°C away 

from the set temperature for more than 15 minutes.

Note: 

Auto Mode is not recommended if this indoor unit is connected to a MXZ 

type outdoor unit. When several indoor units are operated simultaneously, 

the unit may not be able to switch operation mode between COOL and 

HEAT. In this case, the indoor unit becomes standby mode (Refer to table 

of Operation indicator lamp).

 COOL mode

Enjoy cool air at your desired temperature. 

Note: 

Do not operate COOL mode at very low outside temperatures (less than 

-10°C). Water condensed in the unit may drip and wet or damage furni

-

ture, etc.

  DRY mode

Dehumidify your room. The room may be cooled slightly. 

Temperature cannot be set during DRY mode.

  HEAT mode

Enjoy warm air at your desired temperature.

Operation indicator lamp

Emergency operation

When the remote controller cannot be used...

Emergency operation can be activated by pressing the emergency operation 

switch (E.O.SW) on the indoor unit.

Each time the E.O.SW is pressed, the operation changes in 

the following order:

1

Press 

 to start the operation.

2

Press 

 to select operation mode. Each press 

changes mode in the following order:

3

Press   or   to set the temperature.

Each press raises or lowers the temperature by 1°C.

 

Press 

 to stop the operation.

•  The same setting is selected the next time by simply pressing

 

.

Auto restart function

If a power failure occurs or the main power is turned off during operation, “Auto 

restart function” automatically starts operation in the same mode as the one 

set with the remote controller just before the shutoff of the main power. When 

timer is set, timer setting is cancelled and the unit starts operation when power 

is resumed.

If you do not want to use this function, please consult the service repre-

sentative because the setting of the unit needs to be changed.

S

ELECTING OPERATION MODES

Set temperature : 24°C

Fan speed : Medium

Horizontal vane : Auto

(AUTO) 

(COOL) 

(DRY) 

(HEAT)

Emergency COOL

Emergency HEAT

Stop

Note:

The  first  30  minutes  of  operation  is  test  run.  Temperature 

control does not work, and fan speed is set to High.

Operation indicator lamp

The operation indicator lamp shows the operation state of the unit.

Indication

Operation state

Room temperature

The unit is operating to reach the set 

temperature

About 2°C or more  

away from set tem-

perature

The room temperature is approach-

ing the set temperature

About 1 to 2°C from 

set temperature

Standby  mode  (only  during  multi 

system operation)

  Lighted 

  Blinking 

  Not lighted

Note:

Multi system operation

Two or more indoor units can be operated by one outdoor unit. When several 

indoor units are operated simultaneously, cooling and heating operations 

cannot be done at the same time. When COOL is selected with one unit and 

HEAT with another or vice versa, the unit selected last goes into standby 

mode.

JG79A796H02_en.indd   4

2013/11/05   15:09:20

Содержание MSZ-GE22VAD

Страница 1: ...ONDITIONERS INDOOR UNIT MSZ GE22VAD MSZ GE25VAD MSZ GE35VAD MSZ GE42VAD MSZ GE50VAD English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating in structions before use ...

Страница 2: ...d altered or repaired by the user An improperly handled air conditioner may cause fire electric shock injury or water leakage etc Consult your dealer If the power supply cord is damaged it must be replaced by the manufacturer or its service agent in order to avoid a hazard When installing relocating or servicing the unit make sure that no substance other than the specified refrigerant R410A enters...

Страница 3: ...er and immediately seek medical atten tion Ensure that the area is well ventilated when the unit is operated together with a combustion appliance Inadequate ventilation may cause oxygen starvation Turn the breaker OFF when you hear thunder and there is a pos sibility of a lightning strike The unit may be damaged if lightning strikes WARNING Consult your dealer for installing the air conditioner It...

Страница 4: ...E OF EACH PART PREPARATION BEFORE OPERATION 1 Press CLOCK 3 Press CLOCK again 2 Press the TIME buttons to set the time Each press increases decreases the time by 1 minute 10 minutes when pressed longer Indoor unit Remote controller Outdoor units may be different in appearance 1 Remove the front lid 2 Insert the negative pole of AAA alkaline batteries first 3 Install the front lid 4 Press RESET Air...

Страница 5: ...es or lowers the temperature by 1 C Press to stop the operation The same setting is selected the next time by simply pressing Auto restart function If a power failure occurs or the main power is turned off during operation Auto restart function automatically starts operation in the same mode as the one set with the remote controller just before the shutoff of the main power When timer is set timer...

Страница 6: ... Swing The vane moves up and down intermittently n To change the horizontal airflow direction Move the vertical vane manually before starting operation 1 Press during COOL ECONO COOL or HEAT mode to select i save mode 2 Set the temperature fan speed and air flow direction The same setting is selected from the next time by simply pressing Two groups of setting can be saved One for COOL ECONO COOL o...

Страница 7: ...ly set 2 C higher it is possible to perform cooling operation with keeping comfort As a result energy can be saved 1 Press or during operation to set the timer ON timer The unit turns ON at the set time OFF timer The unit turns OFF at the set time or blinks Make sure that the current time is set correctly Page 3 2 Press Increase and Decrease to set the time of timer Each press increases or decreas...

Страница 8: ...ustration Wipe with a soft dry cloth or rinse it with water Do not soak it in water for more than two hours Dry it well in shade 3 Install the front panel by following the removal pro cedure in reverse Close the front panel securely and press the positions indicated by the arrows Hole Hinge Air filter Catechin air filter Clean every 2 weeks Remove dirt by a vacuum cleaner or rinse with water Dry i...

Страница 9: ...ly to maintain sufficient cooling capacity Water leaks from the outdoor unit During COOL and DRY operations pipe or pipe connecting sections are cooled and this causes water to condense In the heating operation water condensed on the heat exchanger drips down In the heating operation the defrosting op eration makes water frozen on the outdoor unit melt and drip down White smoke is discharged from ...

Страница 10: ...ore TV Cordless phone or Portable phone 3 m or more 1 m or more The installation location of the outdoor unit should be at least 3 m away from the antennas for TV sets radios etc In areas where the reception is weak provide greater space between the outdoor unit and the antenna of the affected device if operation of the air conditioner interferes with radio or TV reception 1 Set to the highest tem...

Страница 11: ......

Страница 12: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN JG79A796H02 ...

Отзывы: