● OPERATING INSTRUCTIONS ●

•  Since rotating parts and parts which could cause an electric shock are used 

in this product, be sure to read these “Safety Precautions” before use.

•  Since the cautionary items shown here are important for safety, be sure to 

observe them.

•  After reading this manual, keep it together with the installation manual in a 

handy place for easy reference.

 

Be sure to receive a guarantee card from your dealer and check that the 

purchased data and shop name, etc. are entered correctly.

Marks and their meanings

 WARNING :

Incorrect  handling  could  cause  serious  hazard,  such  as 

death, serious injury, etc. with a high probability.

 CAUTION :

Incorrect handling could cause serious hazard depending 

on the conditions.

Meanings of symbols used in this manual

 :  Be sure not to do.

 :  Be sure to follow the instruction.

 :  Never insert your finger or stick, etc.

 :  Never step onto the indoor/outdoor unit and do not put anything on them.

 :  Danger of electric shock. Be careful.

 :  Be sure to disconnect the power supply plug from the power outlet.

 :  Be sure to shut off the power.

S

AFETY PRECAUTIONS

C

ONTENTS

n

 SAFETY PRECAUTIONS 

1

n

 NAME OF EACH PART 

3

n

 PREPARATION BEFORE OPERATION 

3

n

 SELECTING OPERATION MODES 

4

n

 FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT 

5

n

 I-SAvE OPERATION  

5

n

 ECONO COOL OPERATION  

6

n

 TIMER OPERATION (ON/OFF TIMER) 

6

n

 CLEANING 

7

n

 WHEN YOU THINK THAT TROUBLE HAS OCCURRED 

8

n

 WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME 

9

n

 INSTALLATION PLACE AND ELECTRICAL WORK 

9

n

 SPECIFICATIONS 

9

 WARNING

Do not connect the power cord to an intermediate point, use 

an  extension  cord,  or  connect  multiple  devices  to  a  single 

AC outlet.

•  This may cause overheating, fire, or electric shock.

Make sure the power plug is free of dirt and insert it securely 

into the outlet.

•  A dirty plug may cause fire or electric shock.

Do not bundle, pull, damage, or modify the power cord, and do 

not apply heat or place heavy objects on it.

•  This may cause fire or electric shock.

Do  not  turn  the  breaker  OFF/ON  or  disconnect/connect  the 

power plug during operation.

•  This may create sparks, which can cause fire.

•  After the indoor unit is switched OFF with the remote controller, 

make sure to turn the breaker OFF or disconnect the power plug. 

Do not expose your body directly to cool air for a prolonged 

length of time.

•  This could be detrimental to your health.

The  unit  should  not  be  installed,  relocated,  disassembled, 

altered, or repaired by the user.

•  An improperly handled air conditioner may cause fire, electric 

shock, injury, or water leakage, etc. Consult your dealer.

•  If the power supply cord is damaged, it must be replaced by the 

manufacturer or its service agent in order to avoid a hazard.

When installing, relocating, or servicing the unit, make sure 

that no substance other than the specified refrigerant (R410A) 

enters the refrigerant circuit.

•  Any presence of foreign substance such as air can cause abnormal 

pressure rise and may result in explosion or injury.

•  The use of any refrigerant other than that specified for the system 

will cause mechanical failure, system malfunction, or unit break-

down. In the worst case, this could lead to a serious impediment 

to securing product safety.

This appliance is not intended for use by persons (including 

children) with reduced physical, sensory or mental capabilities, 

or lack of experience and knowledge, unless they have been 

given supervision or instruction concerning use of the appli-

ance by a person responsible for their safety.
Children should be supervised to ensure that they do not play 

with the appliance.

  

Do not insert your finger, a stick, or other objects into the air 

inlet or outlet.

•  This may cause injury, since the fan inside rotates at high speeds 

during operation.

  

In case of an abnormal condition (such as a burning smell), 

stop the air conditioner and disconnect the power plug or turn 

the breaker OFF.

•  A continued operation in the abnormal state may cause a malfunc-

tion, fire, or electric shock. In this case, consult your dealer.

When the air conditioner does not cool or heat, there is a pos-

sibility of refrigerant leakage. In this case, consult your dealer. 

If a repair involves recharging the unit with refrigerant, ask the 

service technician for details.

•  The refrigerant used in the air conditioner is safe. Normally, it does 

not leak. However, if refrigerant leaks and comes in contact with 

a heat source such as a fan heater, kerosene heater, or cooking 

stove, it will create a harmful gas.

The user should never attempt to wash the inside of the indoor 

unit.  Should  the  inside  of  the  unit  require  cleaning,  contact 

your dealer.

•  Unsuitable detergent may cause damage to plastic material inside 

the unit, which may result in water leakage. Should detergent 

come in contact with electrical parts or the motor, it will result in 

a malfunction, smoke, or fire.

 CAUTION

Do not touch the air inlet or the aluminum fins of the indoor/

outdoor unit.

•  This may cause injury.

Do not use insecticides or flammable sprays on the unit.

•  This may cause a fire or deformation of the unit.

JG79A796H02_en.indd   1

2013/11/05   15:09:17

Содержание MSZ-GE22VAD

Страница 1: ...ONDITIONERS INDOOR UNIT MSZ GE22VAD MSZ GE25VAD MSZ GE35VAD MSZ GE42VAD MSZ GE50VAD English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating in structions before use ...

Страница 2: ...d altered or repaired by the user An improperly handled air conditioner may cause fire electric shock injury or water leakage etc Consult your dealer If the power supply cord is damaged it must be replaced by the manufacturer or its service agent in order to avoid a hazard When installing relocating or servicing the unit make sure that no substance other than the specified refrigerant R410A enters...

Страница 3: ...er and immediately seek medical atten tion Ensure that the area is well ventilated when the unit is operated together with a combustion appliance Inadequate ventilation may cause oxygen starvation Turn the breaker OFF when you hear thunder and there is a pos sibility of a lightning strike The unit may be damaged if lightning strikes WARNING Consult your dealer for installing the air conditioner It...

Страница 4: ...E OF EACH PART PREPARATION BEFORE OPERATION 1 Press CLOCK 3 Press CLOCK again 2 Press the TIME buttons to set the time Each press increases decreases the time by 1 minute 10 minutes when pressed longer Indoor unit Remote controller Outdoor units may be different in appearance 1 Remove the front lid 2 Insert the negative pole of AAA alkaline batteries first 3 Install the front lid 4 Press RESET Air...

Страница 5: ...es or lowers the temperature by 1 C Press to stop the operation The same setting is selected the next time by simply pressing Auto restart function If a power failure occurs or the main power is turned off during operation Auto restart function automatically starts operation in the same mode as the one set with the remote controller just before the shutoff of the main power When timer is set timer...

Страница 6: ... Swing The vane moves up and down intermittently n To change the horizontal airflow direction Move the vertical vane manually before starting operation 1 Press during COOL ECONO COOL or HEAT mode to select i save mode 2 Set the temperature fan speed and air flow direction The same setting is selected from the next time by simply pressing Two groups of setting can be saved One for COOL ECONO COOL o...

Страница 7: ...ly set 2 C higher it is possible to perform cooling operation with keeping comfort As a result energy can be saved 1 Press or during operation to set the timer ON timer The unit turns ON at the set time OFF timer The unit turns OFF at the set time or blinks Make sure that the current time is set correctly Page 3 2 Press Increase and Decrease to set the time of timer Each press increases or decreas...

Страница 8: ...ustration Wipe with a soft dry cloth or rinse it with water Do not soak it in water for more than two hours Dry it well in shade 3 Install the front panel by following the removal pro cedure in reverse Close the front panel securely and press the positions indicated by the arrows Hole Hinge Air filter Catechin air filter Clean every 2 weeks Remove dirt by a vacuum cleaner or rinse with water Dry i...

Страница 9: ...ly to maintain sufficient cooling capacity Water leaks from the outdoor unit During COOL and DRY operations pipe or pipe connecting sections are cooled and this causes water to condense In the heating operation water condensed on the heat exchanger drips down In the heating operation the defrosting op eration makes water frozen on the outdoor unit melt and drip down White smoke is discharged from ...

Страница 10: ...ore TV Cordless phone or Portable phone 3 m or more 1 m or more The installation location of the outdoor unit should be at least 3 m away from the antennas for TV sets radios etc In areas where the reception is weak provide greater space between the outdoor unit and the antenna of the affected device if operation of the air conditioner interferes with radio or TV reception 1 Set to the highest tem...

Страница 11: ......

Страница 12: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN JG79A796H02 ...