Mitsubishi Electric MSZ-GE22VAD Скачать руководство пользователя страница 8

En-

● OPERATING INSTRUCTIONS ●

Air outlet and Fan (before cleaning, make sure that the fan is stopped)

C

LEANING

1

Turn the horizontal vanes down-

ward. Then, remove the upper 

vane as shown in 

➀ 

and 

.

•  Repeat 

➀ 

and 

➁ 

for the lower vane.

2

Swing out the two vertical vanes 

one by one.

4

Put the vertical vanes back to their 

original positions correctly one by 

one, into their respective guide.

•  Push the vanes until they click into place.

5

Install the horizontal vane by 

following the removal procedure 

in reverse.

•  If the horizontal vane is not installed cor-

rectly, all LED lamps blink when power is 

turned on.

Note:

Do  not  apply  excessive  force  to  the  fan  or  fan 

guard.

Lower vane

Upper vane

Unlock

Guide

 Important

• 

Clean the filters regularly for best performance and to 

reduce power consumption.

• 

Dirty filters cause condensation in the air conditioner 

which  will  contribute  to  the  growth  of  fungi  such  as 

mold. It is therefore recommended to clean air filters 

every 2 weeks.

Instructions:

 

•  Switch off the power supply or turn off the breaker before cleaning.

•  Be careful not to touch the metal parts with your hands.

•  Do not use benzine, thinner, polishing powder, or insecticide.

•  Use only diluted mild detergents.

•  Do not expose parts to direct sunlight, heat, or fire to dry.

•  Do not use water hotter than 50°C.

Front panel

1. Lift the front panel until a “click” is heard.

2. Hold the hinges and pull to remove as shown in the above 

illustration.

•  Wipe with a soft dry cloth or rinse it with water.

•  Do not soak it in water for more than two hours.

•  Dry it well in shade.

3. Install the front panel by following the removal pro-

cedure in reverse. Close the front panel securely 

and press the positions indicated by the arrows.

Hole

Hinge

Air filter (Catechin air filter)

• 

 

Clean every 2 weeks

 

•  Remove dirt by a vacuum cleaner, or rinse with water.

•  Dry it well in shade.

Air cleaning filter 

 

(Anti-Allergy Enzyme Filter, option)

Back side of air filter 

Every 3 months:

•  Remove dirt by a vacuum cleaner.

When dirt cannot be removed by 

vacuum cleaning:

• 

Soak the filter and its frame in luke

-

warm water before rinsing it.

•  After  washing,  dry  it  well  in  shade. 

Install all tabs of air filter.

Every year:

•  Replace it with a new air cleaning filter for best performance.

•  Parts Number 

 MAC-408FT-E 

What is “Catechin air filter” ?

Catechin is a bioflavonoid that is found in green tea that has both antivi

-

ral and antioxidant qualities. In addition to these benefits, Catechin also 

offers excellent deodorizing characteristics. Catechin air filter uses this 

compound to not only improve air quality but also prevent the spread of 

bacteria and viruses in the room.

Pull to remove from the air filter

3

Clean the air outlet and fan.

•  Wipe with a soft dry cloth.

Clean the fan.

•  Use the QUICK CLEAN KIT (option).

  Parts Number 

 MAC-093SS-E 

•  Refer to the instructions described in the  

QUICK CLEAN KIT for details.

Heat exchanger

•  Wear gloves to protect your hands.

•  Use the QUICK CLEAN KIT  

(option).

  Parts Number 

 MAC-093SS-E 

•  Refer to the instructions described in 

the  QUICK CLEAN KIT for details.

JG79A796H02_en.indd   7

2013/11/05   15:09:24

Содержание MSZ-GE22VAD

Страница 1: ...ONDITIONERS INDOOR UNIT MSZ GE22VAD MSZ GE25VAD MSZ GE35VAD MSZ GE42VAD MSZ GE50VAD English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating in structions before use ...

Страница 2: ...d altered or repaired by the user An improperly handled air conditioner may cause fire electric shock injury or water leakage etc Consult your dealer If the power supply cord is damaged it must be replaced by the manufacturer or its service agent in order to avoid a hazard When installing relocating or servicing the unit make sure that no substance other than the specified refrigerant R410A enters...

Страница 3: ...er and immediately seek medical atten tion Ensure that the area is well ventilated when the unit is operated together with a combustion appliance Inadequate ventilation may cause oxygen starvation Turn the breaker OFF when you hear thunder and there is a pos sibility of a lightning strike The unit may be damaged if lightning strikes WARNING Consult your dealer for installing the air conditioner It...

Страница 4: ...E OF EACH PART PREPARATION BEFORE OPERATION 1 Press CLOCK 3 Press CLOCK again 2 Press the TIME buttons to set the time Each press increases decreases the time by 1 minute 10 minutes when pressed longer Indoor unit Remote controller Outdoor units may be different in appearance 1 Remove the front lid 2 Insert the negative pole of AAA alkaline batteries first 3 Install the front lid 4 Press RESET Air...

Страница 5: ...es or lowers the temperature by 1 C Press to stop the operation The same setting is selected the next time by simply pressing Auto restart function If a power failure occurs or the main power is turned off during operation Auto restart function automatically starts operation in the same mode as the one set with the remote controller just before the shutoff of the main power When timer is set timer...

Страница 6: ... Swing The vane moves up and down intermittently n To change the horizontal airflow direction Move the vertical vane manually before starting operation 1 Press during COOL ECONO COOL or HEAT mode to select i save mode 2 Set the temperature fan speed and air flow direction The same setting is selected from the next time by simply pressing Two groups of setting can be saved One for COOL ECONO COOL o...

Страница 7: ...ly set 2 C higher it is possible to perform cooling operation with keeping comfort As a result energy can be saved 1 Press or during operation to set the timer ON timer The unit turns ON at the set time OFF timer The unit turns OFF at the set time or blinks Make sure that the current time is set correctly Page 3 2 Press Increase and Decrease to set the time of timer Each press increases or decreas...

Страница 8: ...ustration Wipe with a soft dry cloth or rinse it with water Do not soak it in water for more than two hours Dry it well in shade 3 Install the front panel by following the removal pro cedure in reverse Close the front panel securely and press the positions indicated by the arrows Hole Hinge Air filter Catechin air filter Clean every 2 weeks Remove dirt by a vacuum cleaner or rinse with water Dry i...

Страница 9: ...ly to maintain sufficient cooling capacity Water leaks from the outdoor unit During COOL and DRY operations pipe or pipe connecting sections are cooled and this causes water to condense In the heating operation water condensed on the heat exchanger drips down In the heating operation the defrosting op eration makes water frozen on the outdoor unit melt and drip down White smoke is discharged from ...

Страница 10: ...ore TV Cordless phone or Portable phone 3 m or more 1 m or more The installation location of the outdoor unit should be at least 3 m away from the antennas for TV sets radios etc In areas where the reception is weak provide greater space between the outdoor unit and the antenna of the affected device if operation of the air conditioner interferes with radio or TV reception 1 Set to the highest tem...

Страница 11: ......

Страница 12: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN JG79A796H02 ...

Отзывы: