Installation place

Avoid installing the air conditioner in the following places.

•  Where there is much machine oil.

•  Salty places such as the seaside.

•  Where sulfide gas is generated such as a hot spring.

•  Where oil is splashed or where the area is filled with oily smoke.(such as cook

-

ing areas and factories, in which the properties of plastic could be changed 

and damaged)

•  Where there is high-frequency or wireless equipment.

•  Where the air from the outdoor unit air outlet is blocked.

•  Where the operation sound or air from the outdoor unit does not bother the 

house next door.

Electrical work

•  Provide an exclusive circuit for the power supply of the air conditioner.

•  Be sure to observe the breaker capacity.

If you have any questions, consult your dealer.

I

NSTALLATION PLACE AND 

ELECTRICAL WORK

S

PECIFICATIONS

To prevent the effects 

of a fluorescent lamp, 

keep as far apart as 

possible.

wall, etc.

Inverter-type 

fluorescent lamp

Keep a space to 
prevent the pic-
ture distortion or 
the noise.

1 m  

or more

Radio

100 mm or 
more

Well-  
ventilated dry 
place

(GE25,35,42/

GE50) 

200/500 mm

or more

Tv

Cordless 
phone or 
Portable 
phone

3 m or 

more

1 m  

or more

The installation location of the outdoor unit should 

be at least 3 m away from the antennas for Tv sets, 

radios, etc. In areas where the reception is weak, 

provide greater space between the outdoor unit and 

the antenna of the affected device if operation of the air 

conditioner interferes with radio or Tv reception.

1

Set to the highest temperature in manual COOL mode, 

and operate for 3 to 4 hours. 

 Page 4 

•  This dries the inside of the unit.

•  Moisture in the air conditioner contributes to growth of fungi, such as 

mold.

2

Press 

 to stop the operation.

3

Turn off the breaker and/or disconnect the power sup-

ply plug.

4

Remove all batteries from the remote controller.

When using the air conditioner again:

1

Clean the air filter. 

 Page 7 

2

Check that the air inlet and outlet of the indoor and 

outdoor units are not blocked.

3

Check that the earth is connected correctly.

4

Refer to the “PREPARATION BEFORE OPERATION”, 

and follow the instructions. 

 Page 3 

W

HEN THE AIR CONDITIONER IS NOT 

GOING TO BE USED FOR A LONG TIME

Indoor

Outdoor

Cooling

Upper limit

32°C DB

23°C WB

46°C DB

Lower limit

21°C DB

15°C WB

-10°C DB

Heating

Upper limit

27°C DB

24°C DB

18°C WB

Lower limit

20°C DB

-15°C DB

-16°C WB

Guaranteed operating range

DB: Dry Bulb

WB: Wet Bulb

JG79A796H02_en.indd   9

2013/11/06   8:53:12

Содержание MSZ-GE22VAD

Страница 1: ...ONDITIONERS INDOOR UNIT MSZ GE22VAD MSZ GE25VAD MSZ GE35VAD MSZ GE42VAD MSZ GE50VAD English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating in structions before use ...

Страница 2: ...d altered or repaired by the user An improperly handled air conditioner may cause fire electric shock injury or water leakage etc Consult your dealer If the power supply cord is damaged it must be replaced by the manufacturer or its service agent in order to avoid a hazard When installing relocating or servicing the unit make sure that no substance other than the specified refrigerant R410A enters...

Страница 3: ...er and immediately seek medical atten tion Ensure that the area is well ventilated when the unit is operated together with a combustion appliance Inadequate ventilation may cause oxygen starvation Turn the breaker OFF when you hear thunder and there is a pos sibility of a lightning strike The unit may be damaged if lightning strikes WARNING Consult your dealer for installing the air conditioner It...

Страница 4: ...E OF EACH PART PREPARATION BEFORE OPERATION 1 Press CLOCK 3 Press CLOCK again 2 Press the TIME buttons to set the time Each press increases decreases the time by 1 minute 10 minutes when pressed longer Indoor unit Remote controller Outdoor units may be different in appearance 1 Remove the front lid 2 Insert the negative pole of AAA alkaline batteries first 3 Install the front lid 4 Press RESET Air...

Страница 5: ...es or lowers the temperature by 1 C Press to stop the operation The same setting is selected the next time by simply pressing Auto restart function If a power failure occurs or the main power is turned off during operation Auto restart function automatically starts operation in the same mode as the one set with the remote controller just before the shutoff of the main power When timer is set timer...

Страница 6: ... Swing The vane moves up and down intermittently n To change the horizontal airflow direction Move the vertical vane manually before starting operation 1 Press during COOL ECONO COOL or HEAT mode to select i save mode 2 Set the temperature fan speed and air flow direction The same setting is selected from the next time by simply pressing Two groups of setting can be saved One for COOL ECONO COOL o...

Страница 7: ...ly set 2 C higher it is possible to perform cooling operation with keeping comfort As a result energy can be saved 1 Press or during operation to set the timer ON timer The unit turns ON at the set time OFF timer The unit turns OFF at the set time or blinks Make sure that the current time is set correctly Page 3 2 Press Increase and Decrease to set the time of timer Each press increases or decreas...

Страница 8: ...ustration Wipe with a soft dry cloth or rinse it with water Do not soak it in water for more than two hours Dry it well in shade 3 Install the front panel by following the removal pro cedure in reverse Close the front panel securely and press the positions indicated by the arrows Hole Hinge Air filter Catechin air filter Clean every 2 weeks Remove dirt by a vacuum cleaner or rinse with water Dry i...

Страница 9: ...ly to maintain sufficient cooling capacity Water leaks from the outdoor unit During COOL and DRY operations pipe or pipe connecting sections are cooled and this causes water to condense In the heating operation water condensed on the heat exchanger drips down In the heating operation the defrosting op eration makes water frozen on the outdoor unit melt and drip down White smoke is discharged from ...

Страница 10: ...ore TV Cordless phone or Portable phone 3 m or more 1 m or more The installation location of the outdoor unit should be at least 3 m away from the antennas for TV sets radios etc In areas where the reception is weak provide greater space between the outdoor unit and the antenna of the affected device if operation of the air conditioner interferes with radio or TV reception 1 Set to the highest tem...

Страница 11: ......

Страница 12: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN JG79A796H02 ...

Отзывы: