background image

Drain hose

Liquid pipe

Gas pipe

Felt tape 

Indoor/outdoor unit
connecting wire 

 CAUTION

Be careful not to make mis-wiring.

Firmly tighten the terminal screws to prevent them from loosening.

After tightening, pull the wires lightly to confirm that they do not move.

If the connecting wire is incorrectly connected to the terminal block, the unit does
not operate normally.

If an earth is incorrect, it may cause an electric shock.

4-5 AUTO RESTART FUNCTION

These models are equipped with an auto restart function. If you do not want to use this
function, please consult the service representative because the setting of the unit needs
to be changed.

When the indoor unit is controlled with the remote controller, the operation mode, the
set temperature, and the fan speed are memorized by the indoor electronic control P.C.
board. The auto restart function sets to work the moment the power has restored after
power failure, then the unit will restart automatically. If the unit is operated in “AUTO”
mode before power failure, the operation mode (COOL, DRY or HEAT) is not stored in
the memory. When the main power is turned on, the unit decides the operation mode
by the initial room temperature at restart and starts operation again.

Operation

1

If the main power (230V AC) has been cut, the operation settings remain.

2

When three minutes have passed after power was restored, the unit will restart
automatically according to the memory.

Notes:

The operation settings are memorized when 10 seconds have passed after the
remote controller was operated.

If the main power is turned off or a power failure occurs while AUTO START/STOP
timer is active, the timer setting is cancelled. As these models are equipped with the
auto restart function, the air conditioner should start operating at the same time that
a power has restored.

If the unit has been off with the remote controller before power failure, the auto
restart function does not work as the power button of the remote controller is off.

To prevent breaker off due to the rush of starting current, systematize other home
appliances not to turn on at the same time.

4-6 PIPE FORMING

Place the drain hose below the refrigerant piping.

Make sure that the drain hose is not heaved or snaked.

Do not pull the hose to apply the tape.

When the drain hose passes the room, be sure to wrap insulation material (obtain-
able at a store) around it.

Wrap the felt tape 

 around the pipe and the drain hose, then put the pipe in the

back space of the indoor unit.

Drain hose

Be careful drain hose is not
heaved.

Cut off in case of right piping.

Cut off in case of downward piping.

Drain cap

FOR REAR, RIGHT OR DOWNWARD PIPING

Pipe arrangement
Put the refrigerant piping and the drain hose together, then apply piping tape 

 to

them.

Insert the piping and the drain hose into the wall hole sleeve 

, and hook the upper

part of the indoor unit on the installation plate 

.

Check if the indoor unit is hooked securely on the installation plate 

 by moving the

unit to left and right.

Thrust the lower part of the indoor unit into the installation plate 

.

FOR LEFT OR LEFT-REAR PIPING

Pipe arrangement
Put the refrigerant piping and the drain hose together, then apply felt tape 

 to them.

REATTACHING DRAIN HOSE

Be sure to reattach the drain hose and the drain cap in case of left or left-rear piping.
Otherwise, it could cause drops of water to drip down from the drain hose.

1 Pull out the drain cap at the rear right of the indoor unit.

Hold the convex section at the end and pull the drain cap.

2 Pull out the drain hose at the rear left of the indoor unit.

Hold the claw marked by the arrow and pull out the drain hose forward.

3 Put the drain cap into the section to which the drain hose is to be

attached at the rear of the indoor unit.

Insert the screwdriver, etc. (not sharp-edged tool) into the hole at the end of the cap and
insert the cap fully into the drain pan.

Cut off in case of left piping.

Felt tape 

Firmly apply felt tape 

 from the end.

(Felt tape 

 overlap width should be 1/3

the tape width.)

Be careful drain
hose is not heaved.

Use a bandage stopper at
the end of felt tape 

.

Drain cap

Drain cap

Firmly apply piping tape 
from the end.

Содержание MSZ-GA50VA

Страница 1: ...r or wall and set the wireless remote controller In rooms where inverter type fluorescent lamps are used the signal from the wireless remote controller may not be received 1 THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY Be sure to read THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY before installing the air conditioner Be sure to observe the cautions specified here as they include importa...

Страница 2: ...D CONNECTIONS This unit has flared connections on both indoor and outdoor sides Remove the outdoor units valve cover then connect the pipe Refrigerant pipes are used to connect the indoor and outdoor units Be careful not to crush or bend the pipe in pipe bending Limits MSZ GA50 60 71 80 Pipe length 30 m max Height difference 15 m max No of bends 10 max Refrigerant adjustment If pipe length exceeds...

Страница 3: ... 3 CONNECTING WIRE SPECIFICATIONS Use special room air conditioning circuit 4 4 INDOOR AND OUTDOOR CONNECTING WIRE CON NECTION You can connect indoor outdoor lead wire without removing the front panel 1 Open the front panel 2 Remove one screw holding the electrical cover then remove the cover 3 Remove the VA clamp and the cord clamp 4 Pass the indoor outdoor unit connecting wire from the back of t...

Страница 4: ... is off To prevent breaker off due to the rush of starting current systematize other home appliances not to turn on at the same time 4 6 PIPE FORMING Place the drain hose below the refrigerant piping Make sure that the drain hose is not heaved or snaked Do not pull the hose to apply the tape When the drain hose passes the room be sure to wrap insulation material obtain able at a store around it Wr...

Страница 5: ...ow Connect the refrigerant piping with the extension pipe Thrust the lower part of the indoor unit into the installation plate 4 7 DRAIN PIPING If the extension drain hose has to pass through a room be sure to wrap it with commercially sold insulation The drain hose should point downward for easy drain flow Fig 1 Do not make drain piping as shown in Fig 2 to 5 Spacer assembly Securely attach the s...

Страница 6: ... substituted for R410A tools The diameter of the service port on the stop valve in outdoor unit has been changed to prevent any other refrigerant being charged into the unit Cap size has been changed from 7 16 UNF with 20 threads to 1 2 UNF with 20 threads R410A tools Can R22 tools be used Description R410A has high pressures beyond the meas urement range of existing gauges Gauge manifold No Port ...

Страница 7: ...perates so the compressor will not operate for three minutes to protect the air conditioner 6 6 EXPLANATION TO THE CUSTOMER Using the OPERATING INSTRUCTIONS explain the following to the customer how to control temperature how to remove the air filters how to remove or put the remote controller in the remote controller holder how to clean precautions for operation etc Recommend the customer to read...

Страница 8: ...e top of the front panel 4 Fit in the bottom of the front panel and tighten it using screws 5 Push the section of the front panel marked by the arrow and fit the panel into the air conditioner 7 2 PUMPING DOWN When relocating or disposing of the air conditioner pump down the system following the procedure below so that no refrigerant is released into the atmosphere 1 Connect the gauge manifold val...

Отзывы: