34
9-7. TEST POINT DIAGRAM AND VOLTAGE
1. Indoor electronic control P.C. board, Indoor terminal P.C. board, Power monitor receiver SW P.C. board
MS-GK24VA MS-GK30VAT
Power monitor receiver SW
P.C. board
Emergency
operation switch
(E.O. SW)
(SW1)
CN20A
(–)
(+)
(Refer to 9-6. .)
Indoor electronic control P.C. board
Indoor terminal P.C. board
Indoor fan motor
(CN211)
311 - 325 - 339 VDC
(–) GND
(high-voltage DC)
15 VDC
(+)3-6 VDC
(+)0 or 15 VDC
Resistor
(R111)
Timer short mode point
JPG JPS (Refer to 7-1.)
Varistor
(NR11)
Terminal
block
To disable "Auto restart function",
cut the Jumper wire to JR77.
(Refer to 7-3.)
Vane motor
(CN151,
CN152)
5 VDC
12 VDC
Room
temperature
thermistor
RT11
(CN111)
Indoor coil thermistor
RT12 (main) (CN112)
Room temperature thermistor (RT11)
Indoor coil thermistor (RT12)
Temperature (°C)
5HVLVWDQFHN
Fuse
(F11)( )
Replace the fuse after removing the indoor terminal P.C. board from the electrical box.
GND
OBH734B