10-2. MS-GK36VAT
NOTE:
Turn OFF the power supply before disassembly.
OPERATING PROCEDURE
PHOTOS/FIGURES
1. Removing the panel
(1) Press and unlock the knobs on both sides of the front
panel and lift the front panel until it is level, and then
pull the hinges forward to remove the front panel.
(2) Remove the screw caps of the panel.
Remove the screws of the panel.
(3) Hold the lower part of both ends on the panel and pull
it slightly toward you, and then remove the panel by
pushing it upward.
(4) Remove the screw of the corner box.
Remove the corner box.
Photo 1
2. Removing the electrical box, the electronic control P.C.
board, the power monitor receiver P.C. board and the
S.W. P.C. board
(1) Remove the panel and the corner box. (Refer to 1.)
(2) Remove the screw of the electrical cover.
Remove the electrical cover.
(3) Remove the screw of the V.A. clamp.
(4) Remove the V.A. clamp, then remove the indoor/ out-
door connecting wire.
(5) Disconnect TAB of the earth wire connected to the
indoor heat exchanger.
(6) Remove the screw of the electrical side cover.
Remove the electrical side cover.
(7) Disconnect all the connectors, TAB and TAB4 on the
indoor electronic control P.C. board.
(8) Remove the screw on lower side of the electrical box.
Remove the electrical box. ( Photo 3.)
(9) Remove the indoor electronic control P.C. board.
(10) Remove the SW holder from the electrical box.
(11) Open the switch holder and pull out the SW P.C.
board.
(12) Remove the power monitor receiver P.C. board holder
from the electrical box.
(13) Open the power monitor receiver P.C. board holder
and pull out the power monitor receiver P.C. board.
Photo 2
40
Screws
Screw of the
corner box
Screw of
electrical side
cover
Power monitor
receiver holder
SW holder
Earth wire to indoor heat
exchanger
Screw of elec-
trical cover
Water cut
Screw of V.A.
clamp
Front panel
OBH734B