7
Item
Function
Capacity
Total input
Service Ref.
Power supply(phase,cycle,voltage)
Input
Running current
Starting current
External finish
Heat exchanger
Fan
Fan(drive)
✕
No.
Fan motor output
Airflow(Low-High)
External static pressure
Booster heater
Operation control & Thermostat
Noise level(Low-High)
Unit drain pipe O.D.
Dimensions
Weight
Service Ref.
Power supply (phase, cycle, voltage)
Input
Running current
Starting current
External finish
Refrigerant control
Compressor
Model
Motor output
Starter type
Protection devices
Heat exchanger
Fan
Fan(drive)
✕
No.
Fan motor output
Airflow
Defrost method
Noise level
Dimensions
Weight
Refrigerant
Charge
Oil<Model>
Pipe size O.D.
Connection method
Between the indoor & outdoor unit
Service Ref.
W
D
H
W
D
H
Liquid
A
(in.)
Gas
A
(in.)
Indoor side
Outdoor side
Height difference
Piping length
INDOOR UNIT
OUTDOOR UNIT
REFRIGERANT
PIPING
W
Btu/h
kW
kW
A
A
kW
m
3
/
X
<CFM>
Pa(mmAq)
kW
>
A
(in.)
A
(in.)
A
(in.)
A
(in.)
kg(lbs)
kW
A
A
kW
kW
m
3
/
X
<CFM>
>
A
(in.)
A
(in.)
A
(in.)
kg(lbs)
kg(lbs)
L
PKH-3FKA-E
Cooling
7,900
27,000
3.25
0.095
0.44
0.80
3.15/3.15
13.82/5.16
Heating
9,100
31,000
3.04
0.095
0.44
0.80
2.94/2.94
12.89/4.81
PKH-3FKA-E
Single, 50Hz, 220-240V
Munsell 3.4Y 7.7/0.8(White)
Plate fin coil
Line flow(direct)
✕
2
0.040
15-20(530-706)
0(direct blow)
—
Remote controller & built-in
39-45
20(13/16)
1,400(55-1/8)
235(9-1/4)
340(13-3/8)
24(53)
PUH-3VKA
2
.UK / PUH-3YKA
2
.UK
Single, 50Hz, 220-240V/3, 50Hz, 380-415V(4wires)
58/37
Munsell 5Y 7/1
Capillary tube
Hermetic
NH52VNDT/NH52YDAT
2.2/2.4
Line start
Internal thermostat, HP switch/Thermal relay, thermal switch
Plate fin coil
Propeller (direct)
✕
1
0.085
50(1,764)
Reverse cycle
52
870(34-1/4)
295+24(11-5/8 add 1)
850(33-7/16)
75(165)
R-22
3.2(7.1)
1.6<MS-32>
9.52(3/8)
15.88(5/8)
Flared
Flared
Max. 50m
Max. 50m
Cooling
Heating
Upper limit
Lower limit
Upper limit
Lower limit
Indoor
35
:
DB, 22.5
:
WB
21
:
DB, 15.5
:
WB
27
:
DB
20
:
DB
Outdoor
46
:
DB
-5
:
DB
21
:
DB, 15.5
:
WB
-8.5
:
DB, -9.5
:
WB
2. Guaranteed operating range
Note1. Rating Conditions (JIS B 8616)
Cooling : Indoor : 27°C (80°F) DB, 19°C (66°F) WB
Outdoor : 35°C (95°F) DB, 24°C (75°F) WB
Heating : Indoor : 20°C (68°F) DB
Outdoor : 7°C (45°F) DB, 6°C (43°F) WB