![Mitsubishi Electric Mr.Slim MSZ09UN W Скачать руководство пользователя страница 49](http://html.mh-extra.com/html/mitsubishi-electric/mr-slim-msz09un-w/mr-slim-msz09un-w_service-manual_1810112049.webp)
49
Check of indoor fan motor
G
When OPERATION INDICATOR lamp flashes 3-time.
Indoor fan does not operate.
Turn OFF the power supply.
Check connector (Fan motor) visually.
Repair or replace the indoor fan motor.
Disconnect lead wires from connector (Fan motor).
Measure resistance between lead wires No.1 and No.3 and then No.2 and No.3 (MSZ09UN).
Are lead wires connected?
Re-connect the lead wires.
Is soldered point of the connector
correctly soldered?
Replace the indoor electronic con-
trol P.C. board.
Re-solder it.
Is resistance 0 (short circuit) or
∞
(open circuit)?
Yes ( 0 or
∞
)
No
(others)
Yes
No
Yes
No
{
}
No.1 and No.4 and then No.3 and No.4 (MSZ12UN).
MSZ12UN
MSZ09UN
Insert screwdriver into air outlet and
rotate indoor fan (motor) slowly for
1 revolution or more, and measure
voltage between CN 121
1
-
2
.
Does voltage repeat 0V
DC and more than 5V?
Yes
No
OB297--2.qxp 04.2.4 4:21 PM Page 49
Содержание Mr.Slim MSZ09UN W
Страница 75: ......