4-5. OPERATING RANGE
(1) POWER SUPPLY
MSZ09UN
MSZ12UN
MUZ09UN
MUZ12UN
Indoor unit
Outdoor unit
Rated voltage
115V 1phase 60Hz
208/230V 1phase 60Hz
Guaranteed Voltage
Model
Min. 103V
Max. 127V
115V
Min. 198V
Max. 253V
208V 230V
4-6. OUTLET AIR SPEED AND COVERAGE RANGE
Model
MSZ09UN
MSZ12UN
Mode
HEAT
COOL
HEAT
COOL
297
279
233
452
452
388
15.8
14.9
12.4
18.2
18.2
15.6
22.3
21.0
17.6
29.2
29.2
25.2
Air flow
(CFM)
Air speed
(ft./sec.)
Coverage
range (ft.)
Function
Dry
Dry
Wet
Dry
Dry
Wet
4-7. ADDITIONAL REFRIGERANT CHARGE R22(oz.)
MSZ09UN
MSZ12UN
MUZ09UN
MUZ12UN
Outdoor unit
precharged
(up to 25ft.)
2 lb. 7 oz.
2 lb. 14 oz.
25ft.
0
30ft.
1.62
35ft.
3.24
Refrigerant piping length (one way)
40ft.
4.86
45ft.
6.48
49ft.
8.10
Model
(2) OPERATION
78%
—
Function
Cooling
Heating
Standard temperature
Maximum temperature
Minimum temperature
Maximum humidity
Standard temperature
Maximum temperature
Minimum temperature
DB (˚F)
80
95
67
70
80
70
WB (˚F)
67
71
57
60
67
60
Indoor
DB (˚F)
95
115
67
47
75
17
WB (˚F)
—
—
—
43
65
15
Outdoor
Condition
Intake air
temperature
●
The air coverage range is the figure up
to the position where the air speed is 1
ft./sec., when air is blown out horizon-
tally from the unit properly at the High
speed position.
The coverage range should be used
only as a general guideline since it
varies according to the size of the room
and furniture arranged inside the room.