(OHFWULFDOVSHFL¿FDWLRQV

MODEL

MSZ-FD09/12NA

INDOOR UNIT

Power supply (V, PHASE, Hz)

208/230, 1, 60

Min. Circuit Ampacity (A)

1.0

Fan motor (F.L.A.)  (A)

0.76

OUTDOOR UNIT

Power supply (V, PHASE, Hz)

208/230, 1, 60

Max. Fuse size (time delay) (A)

15

Min. Circuit Ampacity  (A)

12

Fan motor (F.L.A.)  (A)

0.56

Compressor

(R.L.A) (A)

8.6

(L.R.A) (A)

10.8

Control voltage

Indoor unit - Remote controller: (Wireless)

Indoor unit - Outdoor unit: DC12-24 V (Polar)

Pipe

Outside

diameter

Minimum

wall thick-

ness

Insulation

thickness

Insulation material

inch (mm)

For liquid

1/4 (6.35)

0.0315
(0.8)

5/16 (8)

Heat resistant foam

SODVWLF6SHFL¿F

gravity

For gas

3/8 (9.52)

0.0315
(0.8)

5/16 (8)

Limits

Pipe length

65 ft. (20 m) max.

Height difference

40 ft. (12 m) max.

No. of bends

10 max.

Pipe length

Up to 25 ft. (7.5 m)

No additional charge is

required.

Exceeding 25 ft. (7.5 m)

Additional charge is required.

(Refer to the table below.)

Refrigerant to be
added

1.62 oz each 5 ft. (30 g/m)

1-3. SPECIFICATIONS

1-3-1. POWER SUPPLY AND INDOOR/OUTDOOR WIRE CONNECTION

• Power should be taken from an exclusive branched circuit.
• Wiring work should be based on applicable technical standards.
• Wiring connections should be made following the diagram.
• Securely tighten screws.

Connecting wires and the ground wire

• Use solid conductor AWG14 or stranded conductor AWG14.
• Use double insulated copper wire with 600 V insulation.
• Use copper conductors only.
* Follow local electrical codes.

Power supply cable and ground wire

• Use solid or stranded conductor AWG14.
• Use copper conductors only.
* Follow local electrical codes.

Note:

When the indoor unit is powered from the outdoor unit, depending on local code, a
disconnect switch needs to be installed to a power supply circuit.

• Refrigerant adjustment... If pipe length exceeds 25 ft. (7.5 m), additional refrigerant

(R410A) charge is required.

(The outdoor unit is charged with refrigerant for pipe length up to 25 ft. [7.5 m])

‡ 7KHXQLWKDVÀDUHGFRQQHFWLRQVRQERWKLQGRRUDQGRXWGRRUVLGHV

• Remove the valve cover from the outdoor unit, then connect the pipe.
• Refrigerant pipes are used to connect the indoor and outdoor units.
• Be careful not to crush or over bend the pipe in pipe bending.

1-3-2. REFRIGERANT PIPES

• To prevent condensation, insulate the two refrigerant pipes.
• Refrigerant pipe bending radius must be 4 in. (100 mm) or more.

 CAUTION

%HVXUHWRXVHWKHLQVXODWLRQRIVSHFL¿HGWKLFNQHVVWDEOHRQWKHULJKW([FHVVLYHLQVXOD

-

tion may cause incorrect installation of the indoor unit, and too little insulation may cause
condensate to form.

1-2. SELECTING THE INSTALLATION LOCATION

INDOOR UNIT 

‡ :KHUHDLUÀRZLVQRWEORFNHG

• Where cool air spreads over the entire room.
• On a rigid wall to reduce the possibility of vibration.
• Where it is not exposed to direct sunlight.
• Where it can be easily drained.
• At a distance 3 ft. (1 m) or more away from a TV and

radio. Operation of the air conditioner may interfere
with radio or TV reception. An amplifier may be re-
quired for the affected device.

• In a place as far away as possible from fluorescent

and incandescent lights (so the infrared remote control
can operate the air conditioner normally).

:KHUHWKHDLU¿OWHUFDQEHUHPRYHGDQGUHSODFHGHDVLO\

Note:

Install the indoor unit high on the wall where air can dis-
tribute over the entire room.

REMOTE CONTROLLER 

• Where it is convenient to operate and easily visible.
• Where children cannot easily touch it.

‡ 6HOHFWDSRVLWLRQDERXWIWPDERYHWKHÀRRU

Check that signals from the remote controller from
that position are received by the indoor unit (‘beep’
or ‘beep beep’ receiving tone sounds). Then, attach
remote controller holder to a pillar or wall and install
wireless remote controller.

Note:

,QURRPVZKHUHLQYHUWHUW\SHÀXRUHVFHQWODPSVDUHXVHG

the signal from the wireless remote controller may not be
received.

OUTDOOR UNIT

• Where it is not overly exposed to strong winds.

‡ :KHUHDLUÀRZLVJRRGDQGGXVWOHVV

• Where neighbours are not annoyed by operation

sound or hot air.

• Where rigid wall or support is available to prevent the

increase of operation sound or vibration.

• Where there is no risk of combustible gas leakage.
• If installing the unit in a location high above the ground,

be sure to secure the unit legs.

• Where it is at least 10 ft. (3 m) away from the antenna

of TV set or radio. Operation of the air conditioner may
interfere with radio or TV reception in areas where re-

FHSWLRQ LV ZHDN $Q DPSOL¿HU PD\ EH UHTXLUHG IRU WKH

affected device.

• Install the unit horizontally.
• Please install it in an area not affected by snowfall or

blowing snow. In areas with heavy snow, please install

DFDQRS\DSHGHVWDODQGRUEDIÀHERDUGV

Note:

• It is advisable to make a piping loop near outdoor unit

so as to reduce vibration.

‡ )RU LQFUHDVHG HI¿FLHQF\ LQVWDOO WKH RXWGRRU XQLW LQ D

location where continuous direct sunlight or excessive
water can be avoided as much as possible.

Note:

When operating the air conditioner in low outside tem-
perature, be sure to follow the instructions described
below.
• Never install the outdoor unit in a place where its air

inlet/outlet side may be exposed directly to wind.

• To prevent exposure to wind, install the outdoor

unit with its air inlet side facing the wall and

DEDIÀH

board on the air outlet side.

Avoid the following places for installation where air
conditioner trouble is liable to occur.

‡ :KHUHÀDPPDEOHJDVFRXOGOHDN

• Where there is an excessive amount of machine oil

in the air.

• Salty places such as the seaside.

‡ :KHUHVXO¿GHJDVLVJHQHUDWHGVXFKDVDKRWVSULQJ

• Where there is high-frequency or wireless equipment.

Содержание Mr. Slim MSZ-FD09NA

Страница 1: ... parts both in the outlet and on the plug Verify that the power supply plug is completely in the outlet If there is dust blockage or loose parts on the power supply plug or the outlet it could FDXVH HOHFWULF VKRFN RU UH I ORRVH SDUWV DUH IRXQG RQ WKH SRZHU VXSSO SOXJ UHSODFH LW N Securely attach the electrical cover to the indoor unit and the service panel to the outdoor unit If the electrical cov...

Страница 2: ...sibility of vibration Where it is not exposed to direct sunlight Where it can be easily drained At a distance 3 ft 1 m or more away from a TV and radio Operation of the air conditioner may interfere with radio or TV reception An amplifier may be re quired for the affected device In a place as far away as possible from fluorescent and incandescent lights so the infrared remote control can operate t...

Страница 3: ...ver D Seal the wall hole gap with putty H Attach the pipe to wall with pipe at tachment strap E Attachment screw F After the leak test apply insulating mate rial tightly so that there is no gap When the piping is to be attached to a wall comprised of tin plate or metal netting use chemically treated wooden piece 25 32 in 20 mm or thicker between the wall and the piping or wrap insulation vinyl tap...

Страница 4: ... A Fig 3 Attach it to the terminal block Be careful not to make mis wiring Attach the wire to the terminal block securely so that its core cannot be seen and no external force affects the connecting section of the terminal block 7 Firmly tighten the terminal screws After tightening verify that the wires are tightly fas tened 8 Secure indoor outdoor unit connecting wire A and the ground wire with c...

Страница 5: ...the section to which the drain hose is to be attached at the rear of the indoor unit Fig 3 Insert a screwdriver into the hole on the cap and insert the cap fully into the drain pan 5 Insert the drain hose fully into the drain pan at the back right of the indoor unit Fig 4 Check if the hose is hooked securely to the projection of its inserting part at the drain pan 6 Insert the drain hose into wall...

Страница 6: ... pipe in the dimension shown in the table Select A mm from the table according to the tool you use 5 Check RPSDUH WKH ÀDUHG ZRUN ZLWK LJ I ÀDUH LV GHIHFWLYH FXW RII WKH VHFWLRQ DQG UHSHDW SURFHGXUH Terminal block Conduit cover Lead wire 3 OUTDOOR UNIT INSTALLATION Power supply cord K Indoor outdoor unit connecting wire A Make earth wire a little longer than others More than 2 3 8 in 60 mm For futu...

Страница 7: ... 7 After refrigerant pipes are connected and evacuated fully open all stop valves on both sides of gas pipe and liquid pipe Operating the unit without fully opening the valves lowers the performance and causes problems 8 Refer to 1 3 SPECIFICATIONS and charge the prescribed amount of refrigerant if needed Be sure to charge slowly with liquid refrigerant Otherwise composition of the refrigerant in ...

Страница 8: ...ws 0 05 to 0 MPa Gauge approx 7 25 to 0 lbf in2 0 5 to 0 kgf cm2 6 Stop the emergency COOL operation Press the E O SW twice to stop the operation 5 RELOCATION AND MAINTENANCE HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN 5 1 REMOVING AND INSTALLING THE PANEL ASSEMBLY Removal procedure 1 Remove the two screws that attach the panel assembly 5HPRYH WKH SDQHO DVVHPEO H VXUH W...

Отзывы: