1-4. INSTALLATION DIAGRAM

ACCESSORIES

Check the following parts before installation.
<Indoor unit>

(1)

Installation plate

1

(2)

Attachment screws for the installa-
tion plate
4 × 25 mm

5

(3)

Remote controller holder

1

(4)

Screws for the remote controller
holder
3.5 × 16 mm (Black)

2

(5)

Battery (AAA) for (6)

2

(6)

Wireless remote controller

1

(7)

Felt tape (For left or left-rear piping)

1

(8)

Anti-Allergy Enzyme Filter

1

(9)

3ODWLQXPGHRGRUL]LQJ¿OWHU

1

FIELD-SUPPLIED PARTS

(A)

Indoor/outdoor unit connecting wire*

1

(B)

Extension pipe

1

(C)

Wall hole sleeve

1

(D)

Wall hole cover

1

(E)

Pipe attachment strap

2 to 5

(F)

Screw for (E) 4 × 20 mm

2 to 5

(G)

Piping tape

1

(H)

Putty

1

(I)

Drain hose
(or soft PVC hose, 19/32 in. [15 mm]
inner diameter or hard PVC pipe
VP16)

2 to 5

(J)

Refrigerant oil

1

(K)

Power supply cord

1

Units should be installed by licensed contractor
according to local code requirements.

Indoor unit

Wall hole
sleeve (C)

Cut off the
extra length.

Pipe attachment
strap (E)

Use the wall hole sleeve
(C) to prevent indoor/out-
door connecting wire (A)
from contacting metal
parts in the wall and to
protect the wiring from
rodents.

Wall hole cover (D)

Seal the wall hole

gap with putty (H).

Attach the pipe to

wall with pipe at-
tachment strap (E).

Attachment screw (F)

After the leak test, apply insulating mate-

rial tightly so that there is no gap.

When the piping is to be attached to a wall

comprised of tin plate or metal netting, use
chemically treated wooden piece 25/32 in.
(20 mm) or thicker between the wall and
the piping, or wrap insulation vinyl tape 7
to 8 turns around the piping.
To use existing piping, perform COOL
operation for 30 minutes and pump down
before removing the old air conditioner.

5HPDNHÀDUHDFFRUGLQJWRWKHGLPHQVLRQ

for new refrigerant.

* Note:

Place indoor/outdoor unit connecting wire (A)
and power supply cord (K) at least 3 ft. (1 m)
away from the TV antenna wire.

5-5/8

in.(60

mm)

or

more/

2-3/8

in.(142.5

mm)

or

more

for

left

and

left

back

piping

(using

spacer)

9/32

in.

(7

mm)

or

more

(B)

Open two sides of
left, right, or rear
side.

4 in.

(100

mm)

or more

14

in.

(350

mm)

or

more

8 in.

(200

mm)

or

more

Basically open 4 in.
(100 mm) or more
without any obstruction
in front and on both
sides of the unit.

4 in.

(100 mm)

or more

Unit: inch

Unit: mm

31-1/2

19-11/16

Air inlet

Air outlet

13-9/16

11-1/4

2-3/8

×

13/16 slot

12-12-3/4

1-9/16

800

500

Air inlet

Air outlet

2-10

×

21 slot

344.5

285

150

40

304-325

5-
15/16

3-5/16

in.(84

mm) or more

3-5/16

in.(84

mm) or more

Содержание Mr. Slim MSZ-FD09NA

Страница 1: ... parts both in the outlet and on the plug Verify that the power supply plug is completely in the outlet If there is dust blockage or loose parts on the power supply plug or the outlet it could FDXVH HOHFWULF VKRFN RU UH I ORRVH SDUWV DUH IRXQG RQ WKH SRZHU VXSSO SOXJ UHSODFH LW N Securely attach the electrical cover to the indoor unit and the service panel to the outdoor unit If the electrical cov...

Страница 2: ...sibility of vibration Where it is not exposed to direct sunlight Where it can be easily drained At a distance 3 ft 1 m or more away from a TV and radio Operation of the air conditioner may interfere with radio or TV reception An amplifier may be re quired for the affected device In a place as far away as possible from fluorescent and incandescent lights so the infrared remote control can operate t...

Страница 3: ...ver D Seal the wall hole gap with putty H Attach the pipe to wall with pipe at tachment strap E Attachment screw F After the leak test apply insulating mate rial tightly so that there is no gap When the piping is to be attached to a wall comprised of tin plate or metal netting use chemically treated wooden piece 25 32 in 20 mm or thicker between the wall and the piping or wrap insulation vinyl tap...

Страница 4: ... A Fig 3 Attach it to the terminal block Be careful not to make mis wiring Attach the wire to the terminal block securely so that its core cannot be seen and no external force affects the connecting section of the terminal block 7 Firmly tighten the terminal screws After tightening verify that the wires are tightly fas tened 8 Secure indoor outdoor unit connecting wire A and the ground wire with c...

Страница 5: ...the section to which the drain hose is to be attached at the rear of the indoor unit Fig 3 Insert a screwdriver into the hole on the cap and insert the cap fully into the drain pan 5 Insert the drain hose fully into the drain pan at the back right of the indoor unit Fig 4 Check if the hose is hooked securely to the projection of its inserting part at the drain pan 6 Insert the drain hose into wall...

Страница 6: ... pipe in the dimension shown in the table Select A mm from the table according to the tool you use 5 Check RPSDUH WKH ÀDUHG ZRUN ZLWK LJ I ÀDUH LV GHIHFWLYH FXW RII WKH VHFWLRQ DQG UHSHDW SURFHGXUH Terminal block Conduit cover Lead wire 3 OUTDOOR UNIT INSTALLATION Power supply cord K Indoor outdoor unit connecting wire A Make earth wire a little longer than others More than 2 3 8 in 60 mm For futu...

Страница 7: ... 7 After refrigerant pipes are connected and evacuated fully open all stop valves on both sides of gas pipe and liquid pipe Operating the unit without fully opening the valves lowers the performance and causes problems 8 Refer to 1 3 SPECIFICATIONS and charge the prescribed amount of refrigerant if needed Be sure to charge slowly with liquid refrigerant Otherwise composition of the refrigerant in ...

Страница 8: ...ws 0 05 to 0 MPa Gauge approx 7 25 to 0 lbf in2 0 5 to 0 kgf cm2 6 Stop the emergency COOL operation Press the E O SW twice to stop the operation 5 RELOCATION AND MAINTENANCE HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN 5 1 REMOVING AND INSTALLING THE PANEL ASSEMBLY Removal procedure 1 Remove the two screws that attach the panel assembly 5HPRYH WKH SDQHO DVVHPEO H VXUH W...

Отзывы: