74
2. AIR CLEANING FILTER
●
AIR CLEANING FILTER removes fine dust of 0.01 micron from air by means of static electricity.
●
Normal life of AIR CLEANING FILTER is 3 months. However, when it becomes dirty, replace it as soon as possible.
●
Clogged AIR CLEANING FILTER may reduce the air conditioner capacity or cause frost on the air outlet.
●
DO NOT reuse AIR CLEANING FILTER even if it is washed.
●
DO NOT remove or attach AIR CLEANING FILTER during unit operation.
3. DEODORIZING FILTER
●
DEODORIZING FILTER removes ammonia and hydrogen sulphide emitted from tobacco, and odors of pets.
●
Clean DEODORIZING FILTER every two weeks. If the filter is particularly dirty, clean the filter more often.
●
For cleaning, soak the filter in warm water for a while, and then wash and rinse it. Dry the filter in the shade thoroughly.
●
When the filter color is still dark even after cleaning, replace the filter with a new one.
Replace the filter at least once a year.
●
DEODORIZING FILTER and AIR CLEANING FILTER can be attached on either side.
Part No.
Model
MAC-1000FT
MSH09NW
Part No.
Model
MAC-1500DF
MSH09NW
MAC-1600DF
MSH12NN,MSH15NN,MSH17NN
MAC-1100FT
MSH12NN,MSH15NN,MSH17NN
OPTIONAL PARTS
14
MAC - 440PI
MAC - 441PI
MAC - 442PI
MAC - 443PI
MAC - 670PI
MAC - 671PI
MAC - 672PI
MAC - 673PI
MAC - 674PI
0
5
0
5
13
C 13/16
D1-1/16
C 1-7/32
D 1-1/16
1/4
3/8
5/8
10ft
16ft
23ft
33ft
10ft
16ft
23ft
33ft
49ft
MSH09NW
Applicable
Model
Part No.
Pipe size O.D
Pipe length
Cross-section
A-Gas(in.)
B-Liquid(in.) Insulation(in.)
Additional
refrigerant
charge
R-22(Oz)
MSH12NN
MSH15NN
MSH17NN
,
1. REFRIGERANT PIPES
The air conditioner has flared connections its on indoor and outdoor sides.
Please use the optional extension pipe as follows.
OB198--3.qxp 24/6/97 6:30 AM Page 74
Содержание Mr. Slim MSH09NW
Страница 2: ......
Страница 72: ...72 1 3 8 11 4 2 13 14 6 7 9 10 17 19 20 15 16 5 OUTDOOR UNIT STRUCTURAL PARTS MUH17NN 18 21 ...