REFRIGERNT SYSTEM DIAGRAM
8
Unit:inch
MSH09NW
INDOOR UNIT
OUTDOOR UNIT
(with heat insulator)
(with heat insulator)
Refrigerant pipe
[
3/8
(Option)
Reversing
valve
Muffler
Stop valve
(with service
port)
Strainer
Refrigerant pipe
[
1/4
(Option)
Stop valve
Capillary tube
O.D. 0.12
✕
I.D.
0.063
✕
19-11/16
Check
valve
Solenoid coil
heating ON
cooling OFF
Flow of refrigerant (cooling)
Flow of refrigerant (heating)
Defrost
thermisor
RT61
Outdoor
heat
exchanger
Room temperature
thermistor
RT11
Indoor coil
thermistor
RT12
Capillary tube
O.D. 0.12
✕
I.D. 0.055
✕
11-13/16
Flared connection
Flared connection
Compressor
Indoor
heat
Accumulator
MSH12NN
MSH15NN
INDOOR UNIT
OUTDOOR UNIT
Indoor
heat
exchanger
Room temperature
thermistor
RT11
Refrigerant pipe
[
5/8
(Option)
Flared connection
Flared connection
Indoor coil
thermistor
RT12
Refrigerant pipe
[
1/4
(Option)
(with heat insulator)
Stop valve
Strainer
Check
valve
Capillary tube
O.D. 0.12
✕
I.D.0.079
✕
7-7/8
Capillary tube
MSH12:O.D. 0.12
✕
I.D 0.071
✕
19-11/16
MSH15:O.D. 0.12
✕
I.D 0.079
✕
23-5/8
Compressor
Accumulator
Stop valve
(with service
port)
Muffler
Outdoor
heat
exchanger
Defrost
thermisor
RT61
Solenoid coil
heating ON
cooling OFF
Flow of refrigerant (cooling)
Flow of refrigerant (heating)
(with heat insulator)
Strainer
Distributor
Reversing
valve
Unit:inch
exchanger
Service
port
Fusible
plug
Service
port
Strainer
Muffler
Fusible
plug
Service
port
Service
port
Capillary tube
O.D. 0.12
✕
I.D.
0.055
✕
11-13/16
Muffler
Capillary tube
O.D. 0.12
✕
I.D.
0.063
✕
35-7/16
MUH09NW
MUH12NN
MUH15NN