44
11-2 Instruction of troubleshooting
Indoor unit oper-
ates. Outdoor unit
doesn’t operate.
Outdoor unit
operates in
only Test
Run opera-
tion.
Outdoor unit
doesn’t oper-
ate even in
Test Run
operation.
Check room
temperature
thermistor.
Refer to
“Check of
outdoor unit”
on page 49.
Indoor unit
dosen’t receive
the signal from
remote
controller.
Refer to
”Check of
receiver P.C.
board” on
page 48.
Indoor unit operation
monitor lamp is flashing.
Indoor unit doesn’t
receive the signal from
remote controller.
Also, operation monitor
lamp doesn’t flash, when
the emergency operation
switch is pressed.
Refer to “Check of
indoor electric control
P.C. board” on page 49.
Cause:indoor/outdoor unit
connecting
Trouble of mis-wiring
Trouble of the serial signal
Cause:Indoor unit
2-time-Room tempera-
ture/Indoor coil
thermistor trouble.
MSH09NW only
3-time-Indoor fan motor
trouble
Refer to
“How to check
mis-wiring and sig-
nal error
(when outdoor unit
doesn’t work)”
on page 50.
❈
1
6-time flash
2.5-second OFF
Cause:outdoor unit
6-time-Replace the out-
door thermistor
E
D
B
Check room temperature
thermistor. Refer to“Test
point diagram and volt-
age” on page 51 and 52.
Refer to
“Check of indoor
fan motor” on
page 47.
Check indoor coil
thermistor. Refer
to“Test point dia-
gram and voltage”
on page 51 and
52.
❈
1<The case of the trouble of the serial signal>
when turn off the power and then turn on the power again, the
indication shows “the trouble of mis-wiring.”
2-time flash
2.5-second OFF
Start
1-time flash
C
A
(
MSH09NW only
3-time flash
2.5-second OFF
MSH12NN
MSH15NN
MSH17NN
When the
remote controller
is pressed or
when the
Emergency
operation switch
is pressed,the
fan does not
rotate,with
Operation indi-
cator lamp on.
OB198--2.qxp 24/6/97 6:02 AM Page 44