background image

En-1

• OPERATING INSTRUCTIONS •

 WARNING

Do not connect the power cord to an intermediate point, 

use an extension cord, or connect multiple devices to a 

single AC outlet.

•  This may cause overheating, fi re, or electric shock.

Make  sure  the  power  plug  is  free  of  dirt  and  insert  it 

securely into the outlet.

•  A dirty plug may cause fi re or electric shock.

Do not bundle, pull, or modify the power cord, and do not 

apply heat or place heavy objects on it.

•  This may cause fi re or electric shock.

Do not turn the breaker OFF/ON or disconnect/connect the 

power plug during operation.

•  This may create sparks, which can cause fi re.

•  After  the  indoor  unit  is  switched  OFF  with  the  remote 

controller, make sure to turn the breaker OFF or disconnect 

the power plug. 

Do not expose your body directly to cool air for a prolonged 

length of time.

•  This could be detrimental to your health.

The  unit  should  not  be  installed,  relocated,  or  repaired 

by the user.

•  An  improperly  handled  air  conditioner  may  cause  fi re  or 

electric shock.

  

Do not insert your fi nger, a stick, or other objects into the 

air inlet or outlet.

•  This may cause injury, since the fan inside rotates at high 

speeds during operation.

•  Since rotating parts and parts which could cause an electric shock are used 

in this product, be sure to read these “Safety Precautions” before use.

•  Since the cautionary items shown here are important for safety, be sure to 

observe them.

•  After reading this manual, keep it together with the installation manual in a 

handy place for easy reference.

•   Be sure to receive a guarantee card from your dealer and check that the

  purchased date and shop name, etc. are entered correctly.

Marks and their meanings

 WARNING :

Incorrect handling could cause serious hazard, such as 

death, serious injury, etc. with a high probability.

 CAUTION :

Incorrect handling could cause serious hazard depending 

on the conditions.

  

In case of an abnormal condition (such as a burning smell), 

stop the air conditioner and disconnect the power plug or 

turn the breaker OFF.

•  A continued operation in the abnormal state may cause a 

malfunction, fi re, or electric shock. In this case, consult your 

dealer.

When the air conditioner does not cool or heat, there is 

a possibility of refrigerant leakage. In this case, consult 

your dealer. If a repair involves recharging the unit with 

refrigerant, ask the service technician for details.

•  The refrigerant used in the air conditioner is safe. Normally, 

it does not leak. However, if refrigerant leaks and comes in 

contact with a heat source such as a fan heater, kerosene 

heater, or cooking stove, it will create a harmful gas.

 CAUTION

Do  not  touch  the  air  inlet  or  the  aluminum  fi ns  of  the 

indoor/outdoor unit.

•  This may cause injury.

Do not use insecticides or fl ammable sprays on the unit.

•  This may cause a fi re or deformation of the unit.

Do not expose pets or houseplants to direct airfl ow.

•  This may cause injury to the pets or plants.

Do not place other electric appliances or furniture under 

the indoor/outdoor unit.

•  Water may drip down from the unit, which may cause damage 

or malfunction.

Do not leave the unit on a damaged installation stand.

•  The unit may fall and cause injury.

Meanings of symbols used in this manual

 :  Be sure not to do.

 :  Be sure to follow the instruction.

 :  Never insert your fi nger or stick, etc.
 :  Never step onto the indoor/outdoor unit and do not put anything on 

them.

 :  Danger of electric shock. Be careful.

 :  Be sure to disconnect the power supply plug from the power outlet.

 :  Be sure to shut off the power.

S

AFETY PRECAUTIONS

C

ONTENTS

 SAFETY PRECAUTIONS 

1

 NAME OF EACH PART 

3

 PREPARATION BEFORE OPERATION 

3

 SELECTING OPERATION MODES 

4

 FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT 

5

 TIMER OPERATION (ON/OFF TIMER) 

5

 CLEANING 

6

 WHEN YOU THINK THAT TROUBLE HAS OCCURRED 

7

 WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME 

8

 INSTALLATION PLACE AND ELECTRICAL WORK 

8

 SPECIFICATIONS 

8

Содержание MR. SLIM MCF-D18VD

Страница 1: ...SD13VD MCF D18VD MCF D24VD English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read this operating instructions before use Ÿà Õ âß π À Ÿ â æ ËÕ â ËÕߪ Õ ËÕßπ ÈÕ à ß Ÿ µâÕß ª Õ Ëπ à à π âÕà π Ÿà Õ â à π È àÕπ â ...

Страница 2: ...epending on the conditions In case of an abnormal condition such as a burning smell stop the air conditioner and disconnect the power plug or turn the breaker OFF A continued operation in the abnormal state may cause a malfunction fire or electric shock In this case consult your dealer When the air conditioner does not cool or heat there is a possibility of refrigerant leakage In this case consult ...

Страница 3: ...he breaker OFF when you hear thunder and there is a possibility of a lightning strike The unit may be damaged if lightning strikes After the air conditioner is used for several seasons perform inspection and maintenance in addition to normal cleaning Dirt or dust in the unit may create an unpleasant odor or clog the drain passage and cause water to leak from the indoor unit Consult your dealer for...

Страница 4: ...eceiving section Emergency operation switch Page 4 Air inlet back and side Piping Drainage hose Air outlet Drain outlet Remote controller holder Signal transmitting section Distance of signal About 6 m Beep s is are heard from the indoor unit when the signal is received Operation display section ON OFF operate stop button Operation select button Page 4 FAN speed control button Page 5 VANE control ...

Страница 5: ...1 to 2 C from set temperature Lighted Not lighted Emergency operation When the remote controller cannot be used Emergency operation can be activated by pressing the emergency operation switch E O SW on the indoor unit Each time the E O SW is pressed the operation changes in the following order 1 Press to start the operation 2 Press to select operation mode Each press changes mode in the following ...

Страница 6: ... time is pressed the set time increases by 1 hour each time is pressed the set time increases by 10 minutes 3 Press or again to cancel timer Note ON and OFF timers can be used in combination mark indicates the order of timer operations If power failure occurs while ON OFF timer is set see page 4 Auto restart function Airflow direction AUTO The vane is set to the most efficient airflow direction Floo...

Страница 7: ...Use only diluted mild detergents Do not expose parts to direct sunlight heat or flames to dry Do not use water hotter than 50 C Air cleaning filter Option If the air cleaning filter is clogged it may lower the unit s capacity or cause condensation at the air outlet capacity or cause condensation at the air outlet The air cleaning filter is disposable If the color of the filter turns brown replace the fi...

Страница 8: ...on Check points Remote controller The display on the remote controller does not appear or it is dim The indoor unit does not respond to the remote control signal Are the batteries exhausted Page 3 Is the polarity of the batteries correct Page 3 Are any buttons on the remote controller of other electric appliances being pressed Does not cool The room cannot be cooled sufficiently Is the temperature ...

Страница 9: ...reception 1 Set to the highest temperature in manual COOL mode and operate for 3 to 4 hours Page 4 This dries the inside of the unit 2 Press to stop the operation 3 Turn off the breaker and or disconnect the power sup ply plug 4 Remove all batteries from the remote controller When using the air conditioner again 1 Clean the air filter Page 6 2 Check that the air inlet and outlet of the indoor and o...

Страница 10: ...ุที ร อนทับบนสายไฟ เพราะอาจก อให เกิดไฟไหม หรือไฟดูดได อย าสับเบรกเกอร เป ด ป ด หรือถอดปลั ก เสียบปลั กในขณะที เครื องกําลังทํางาน เพราะอาจก อให เกิดไฟไหม เนื องจากประกายไฟได ให แน ใจว าได สับเบรกเกอร ลงแล ว หรือถอดปลั กไฟออกแล ว หลังจากที ได ป ดเครื องภายในอาคารด วยรีโมทคอนโทรล อย าทำให ผิวหนังสัมผัสกับอากาศเย นโดยตรงเป นเวลานาน เพราะอาจทําให ไม สบายได อย าติดตั ง เคลื อนย าย หรือซ อมเครื องด วยต...

Страница 11: ...ม การระบายอากาศที ไม ดีเพียงพออาจทําให เกิดภาวะขาดออกซิเจนได สับเบรกเกอร ลง หากท านได ยินเสียงฟ าร อง และมีความเป นไป ได ที จะเกิดฟ าผ า เครื องอาจชํารุด หากโดนฟ าผ า หลังจากใช เครื องปรับอากาศมาเป นเวลานาน ควรตรวจสภาพและ ทําการบํารุงรักษานอกเหนือไปจากการทําความสะอาดตามปกติ สิ งสกปรกหรือฝุ นในตัวเครื องอาจก อให เกิดกลิ นอันไม พึงประสงค หรืออุดตันทางระบายน ำ และทําให มีน ำรั วจากเครื องภายในอาคาร โ...

Страница 12: ... 2 กดปุ ม และปุ ม เพ อตั งเวลา แต ละครั งที กดปุ ม เวลาที ตั ง จะเพิ มครั งละ 1 ชั วโมง และแต ละครั งที กดปุ ม เวลาที ตั ง และลดครั งละ 1 นาที 4 RESET ก อนใช งาน เสียบปลั กไฟเข ากับเต ารับ และ หรือสับเบรกเกอร ขึ น การใส แบตเตอรี ในรีโมทคอนโทรล การตั งเวลาป จจุบัน ฝาครอบด านหน า ช องลมเข า เมื อติดตั งบนเพดาน สวิตช การทำงานฉุกเฉิน หน า 4 แผ นกรองอากาศ แผ นกรองฟอกอากาศ อุปกรณ เสริม แผ นฟอกอากาศกําจั...

Страница 13: ...ูมิ ที ตั งไว ประมาณ 1 หรือ 2 องศาเซลเซียส สว าง ไม สว าง ระบบการทำงานฉุกเฉิน เม อไม สามารถใช งานรีโมทคอนโทรลได ท านสามารถใช ระบบการทํางานฉุกเฉินได โดยการกดสวิตช การทํางานฉุกเฉิน E O SW ที เคร องภายในอาคาร แต ละครั งที กดปุ ม E O SW โหมดการทํางานจะเปลี ยนไปตามลําดับดังนี 1 กดปุ ม เพ อเริ มการทํางาน 2 กดปุ ม เพ อเลือกโหมดการทํางาน เม อกดปุ มแต ละครั ง โหมดจะเปลี ยนไปตามลําดับดังนี 3 กดปุ ม หรือ เพ ...

Страница 14: ...1 โดยอัตโนมัติหลังจาก 1 ชั วโมงผ านไป เพ อป องกันน ำหยด สวิง บานเกล ดจะเล อนขึ นและลงเป นระยะๆ การเปลี ยนทิศทางลมในแนวขึ น ลง ขยับบานเกล ดปรับทิศทางลมซ าย ขวาเอง ก อนที จะเป ดเคร อง I FEEL COOL DRY FAN I FEEL COOL DRY FAN AMPM AMPM การตั งเวลาเป ด ป ดเคร อง การตั งเวลา ON OFF 1 กดปุ ม หรือ ในขณะที เคร องกำลังทำงานเพ อตั งเวลา การตั งเวลา ON ตัวเคร องจะเป ด ON ตามเวลา ที ตั งไว การตั งเวลา OFF ตัวเ...

Страница 15: ...าน การทำความสะอาด ป ดสวิตช แหล งจ ายไฟ หรือสับเบรกเกอร ลงก อนทำความสะอาด ระวังอย าสัมผัสชิ นส วนที เป นโลหะด วยมือเปล า ห ามใช น ำมันเบนซิน ทินเนอร ผงขัด หรือยาฆ าแมลง ใช น ำผสมผงซักฟอกเจือจางเท านั น ห ามทำให ชิ นส วนต างๆ โดนแสงแดดส องโดยตรง โดนความร อน หรือเปลวไฟเพื อทำให แห ง ห ามใช น ำที มีความร อนเกิน 50 C แผ นฟอกอากาศกำจัดกลิ น อุปกรณ เสริม ด านหลังของแผ นกรองอากาศ ทำความสะอาดทุก 2 เดือน แช...

Страница 16: ...ื น ท อและจุดเชื อมท อ ต างๆ จะเย นตัวทำให ไอน ำเกิดการกลั นตัวได อาการ รายละเอียดและจุดตรวจสอบ รีโมทคอนโทรล ไม มีผลแสดงการทำงานที รีโมทคอนโทรลหรือไม ชัด เครื อง ปรับอากาศภายในไม ตอบสนอง ต อสัญญาณของรีโมทคอนโทรล แบตเตอรี หมดหรือไม หน า 3 ใส แบตเตอรี ถูกขั วหรือไม หน า 3 มีการกดปุ มรีโมทคอนโทรลของเครื องใช ไฟฟ า ชนิดอื นหรือไม อากาศไม เย น เครื องปรับอากาศทำความเย น ไม เพียงพอ อุณหภูมิที ตั งไว เหม...

Страница 17: ...เครื อง 2 กดปุ ม เพื อหยุดการทำงาน 3 สับเบรกเกอร ลง และ หรือถอดปลั กไฟออก 4 ถอดแบตเตอรี ทั งหมดออกจากรีโมทคอนโทรล เมื อเริ มใช เครื องปรับอากาศอีกครั ง 1 ทำความสะอาดแผ นกรองอากาศ หน า 6 2 ตรวจสอบว าไม มีสิ งกีดขวางที ช องลมเข า และช องลมออกของเครื อง ภายในและภายนอกอาคาร 3 ตรวจสอบว าต อสายดินถูกต องแล ว เม อไม ได ใช เคร องปรับอากาศ เป นเวลานาน รุ น MCF SD13VD MCF D18VD MCF D24VD ขนาด สูง กว าง ลึก ...

Страница 18: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN VN79B582H01 ...

Отзывы: