background image

En-4

 I FEEL mode

The unit selects the operation mode according to the room temperature 

when I FEEL is selected. When the room temperature is higher than 25°C, 

COOL is selected (set temperature: 24°C). When the room temperature is 

lower than 25°C, DRY is selected. However, when operation is stopped and 

then started within 2 hours, the mode which has been selected previously 

is operated.

Note: 

During COOL operation, the set temperature may not be changed when 

the room temperature is more than 2°C higher than the set temperature. 

In this case, please wait until the room temperature drops to within 2°C of 

the set temperature.

 COOL mode

Enjoy cool air at your desired temperature. 

  DRY mode

Dehumidify your room. The room may be cooled slightly. 

Temperature cannot be set during DRY mode.

  FAN mode

Circulate the air in your room.

Operation indicator lamp

Operation indicator lamp

The operation indicator lamp shows the operation state of the unit.

Indication

Operation state

Room temperature

The unit is operating to reach the set 

temperature

About 2°C or more  away 

from set temperature

The room temperature is approaching 

the set temperature

About 1 to 2°C from set 

temperature

  Lighted 

  Not lighted

Emergency operation

When the remote controller cannot be used...

Emergency operation can be activated by pressing the emergency operation 

switch (E.O.SW) on the indoor unit.

Each time the E.O.SW is pressed, the operation changes in 

the following order:

1

Press 

 to start the operation.

2

Press 

 to select operation mode. Each press 

changes mode in the following order:

3

Press   or   to set the temperature.

Each press raises or lowers the temperature by 1°C.

 

Press 

 to stop the operation.

•  The same setting is selected the next time by simply pressing

 

.

Auto restart function

If a power failure occurs or the main power is turned off during operation, “Auto 

restart function” automatically starts operation in the same mode as the one set 

with

 

the remote controller

 just before the shutoff of the main power. When 

timer is set, timer setting is cancelled and the unit starts operation when power 

is resumed.

If  you  do  not  want  to  use  this  function,  please  consult  the  service 

representative because the setting of the unit needs to be changed.

S

ELECTING OPERATION MODES

Set temperature : 24°C

Fan speed : Medium

Horizontal vane : Auto

(I FEEL)

(COOL)

(DRY)

(FAN)

Emergency COOL

Stop

Note:

The  fi rst  30  minutes  of  operation  is  test  run.  Temperature 

control does not work, and fan speed is set to High.

I FEEL COOL

DRY

FAN

AMPM

AMPM

Содержание MR. SLIM MCF-D18VD

Страница 1: ...SD13VD MCF D18VD MCF D24VD English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read this operating instructions before use Ÿà Õ âß π À Ÿ â æ ËÕ â ËÕߪ Õ ËÕßπ ÈÕ à ß Ÿ µâÕß ª Õ Ëπ à à π âÕà π Ÿà Õ â à π È àÕπ â ...

Страница 2: ...epending on the conditions In case of an abnormal condition such as a burning smell stop the air conditioner and disconnect the power plug or turn the breaker OFF A continued operation in the abnormal state may cause a malfunction fire or electric shock In this case consult your dealer When the air conditioner does not cool or heat there is a possibility of refrigerant leakage In this case consult ...

Страница 3: ...he breaker OFF when you hear thunder and there is a possibility of a lightning strike The unit may be damaged if lightning strikes After the air conditioner is used for several seasons perform inspection and maintenance in addition to normal cleaning Dirt or dust in the unit may create an unpleasant odor or clog the drain passage and cause water to leak from the indoor unit Consult your dealer for...

Страница 4: ...eceiving section Emergency operation switch Page 4 Air inlet back and side Piping Drainage hose Air outlet Drain outlet Remote controller holder Signal transmitting section Distance of signal About 6 m Beep s is are heard from the indoor unit when the signal is received Operation display section ON OFF operate stop button Operation select button Page 4 FAN speed control button Page 5 VANE control ...

Страница 5: ...1 to 2 C from set temperature Lighted Not lighted Emergency operation When the remote controller cannot be used Emergency operation can be activated by pressing the emergency operation switch E O SW on the indoor unit Each time the E O SW is pressed the operation changes in the following order 1 Press to start the operation 2 Press to select operation mode Each press changes mode in the following ...

Страница 6: ... time is pressed the set time increases by 1 hour each time is pressed the set time increases by 10 minutes 3 Press or again to cancel timer Note ON and OFF timers can be used in combination mark indicates the order of timer operations If power failure occurs while ON OFF timer is set see page 4 Auto restart function Airflow direction AUTO The vane is set to the most efficient airflow direction Floo...

Страница 7: ...Use only diluted mild detergents Do not expose parts to direct sunlight heat or flames to dry Do not use water hotter than 50 C Air cleaning filter Option If the air cleaning filter is clogged it may lower the unit s capacity or cause condensation at the air outlet capacity or cause condensation at the air outlet The air cleaning filter is disposable If the color of the filter turns brown replace the fi...

Страница 8: ...on Check points Remote controller The display on the remote controller does not appear or it is dim The indoor unit does not respond to the remote control signal Are the batteries exhausted Page 3 Is the polarity of the batteries correct Page 3 Are any buttons on the remote controller of other electric appliances being pressed Does not cool The room cannot be cooled sufficiently Is the temperature ...

Страница 9: ...reception 1 Set to the highest temperature in manual COOL mode and operate for 3 to 4 hours Page 4 This dries the inside of the unit 2 Press to stop the operation 3 Turn off the breaker and or disconnect the power sup ply plug 4 Remove all batteries from the remote controller When using the air conditioner again 1 Clean the air filter Page 6 2 Check that the air inlet and outlet of the indoor and o...

Страница 10: ...ุที ร อนทับบนสายไฟ เพราะอาจก อให เกิดไฟไหม หรือไฟดูดได อย าสับเบรกเกอร เป ด ป ด หรือถอดปลั ก เสียบปลั กในขณะที เครื องกําลังทํางาน เพราะอาจก อให เกิดไฟไหม เนื องจากประกายไฟได ให แน ใจว าได สับเบรกเกอร ลงแล ว หรือถอดปลั กไฟออกแล ว หลังจากที ได ป ดเครื องภายในอาคารด วยรีโมทคอนโทรล อย าทำให ผิวหนังสัมผัสกับอากาศเย นโดยตรงเป นเวลานาน เพราะอาจทําให ไม สบายได อย าติดตั ง เคลื อนย าย หรือซ อมเครื องด วยต...

Страница 11: ...ม การระบายอากาศที ไม ดีเพียงพออาจทําให เกิดภาวะขาดออกซิเจนได สับเบรกเกอร ลง หากท านได ยินเสียงฟ าร อง และมีความเป นไป ได ที จะเกิดฟ าผ า เครื องอาจชํารุด หากโดนฟ าผ า หลังจากใช เครื องปรับอากาศมาเป นเวลานาน ควรตรวจสภาพและ ทําการบํารุงรักษานอกเหนือไปจากการทําความสะอาดตามปกติ สิ งสกปรกหรือฝุ นในตัวเครื องอาจก อให เกิดกลิ นอันไม พึงประสงค หรืออุดตันทางระบายน ำ และทําให มีน ำรั วจากเครื องภายในอาคาร โ...

Страница 12: ... 2 กดปุ ม และปุ ม เพ อตั งเวลา แต ละครั งที กดปุ ม เวลาที ตั ง จะเพิ มครั งละ 1 ชั วโมง และแต ละครั งที กดปุ ม เวลาที ตั ง และลดครั งละ 1 นาที 4 RESET ก อนใช งาน เสียบปลั กไฟเข ากับเต ารับ และ หรือสับเบรกเกอร ขึ น การใส แบตเตอรี ในรีโมทคอนโทรล การตั งเวลาป จจุบัน ฝาครอบด านหน า ช องลมเข า เมื อติดตั งบนเพดาน สวิตช การทำงานฉุกเฉิน หน า 4 แผ นกรองอากาศ แผ นกรองฟอกอากาศ อุปกรณ เสริม แผ นฟอกอากาศกําจั...

Страница 13: ...ูมิ ที ตั งไว ประมาณ 1 หรือ 2 องศาเซลเซียส สว าง ไม สว าง ระบบการทำงานฉุกเฉิน เม อไม สามารถใช งานรีโมทคอนโทรลได ท านสามารถใช ระบบการทํางานฉุกเฉินได โดยการกดสวิตช การทํางานฉุกเฉิน E O SW ที เคร องภายในอาคาร แต ละครั งที กดปุ ม E O SW โหมดการทํางานจะเปลี ยนไปตามลําดับดังนี 1 กดปุ ม เพ อเริ มการทํางาน 2 กดปุ ม เพ อเลือกโหมดการทํางาน เม อกดปุ มแต ละครั ง โหมดจะเปลี ยนไปตามลําดับดังนี 3 กดปุ ม หรือ เพ ...

Страница 14: ...1 โดยอัตโนมัติหลังจาก 1 ชั วโมงผ านไป เพ อป องกันน ำหยด สวิง บานเกล ดจะเล อนขึ นและลงเป นระยะๆ การเปลี ยนทิศทางลมในแนวขึ น ลง ขยับบานเกล ดปรับทิศทางลมซ าย ขวาเอง ก อนที จะเป ดเคร อง I FEEL COOL DRY FAN I FEEL COOL DRY FAN AMPM AMPM การตั งเวลาเป ด ป ดเคร อง การตั งเวลา ON OFF 1 กดปุ ม หรือ ในขณะที เคร องกำลังทำงานเพ อตั งเวลา การตั งเวลา ON ตัวเคร องจะเป ด ON ตามเวลา ที ตั งไว การตั งเวลา OFF ตัวเ...

Страница 15: ...าน การทำความสะอาด ป ดสวิตช แหล งจ ายไฟ หรือสับเบรกเกอร ลงก อนทำความสะอาด ระวังอย าสัมผัสชิ นส วนที เป นโลหะด วยมือเปล า ห ามใช น ำมันเบนซิน ทินเนอร ผงขัด หรือยาฆ าแมลง ใช น ำผสมผงซักฟอกเจือจางเท านั น ห ามทำให ชิ นส วนต างๆ โดนแสงแดดส องโดยตรง โดนความร อน หรือเปลวไฟเพื อทำให แห ง ห ามใช น ำที มีความร อนเกิน 50 C แผ นฟอกอากาศกำจัดกลิ น อุปกรณ เสริม ด านหลังของแผ นกรองอากาศ ทำความสะอาดทุก 2 เดือน แช...

Страница 16: ...ื น ท อและจุดเชื อมท อ ต างๆ จะเย นตัวทำให ไอน ำเกิดการกลั นตัวได อาการ รายละเอียดและจุดตรวจสอบ รีโมทคอนโทรล ไม มีผลแสดงการทำงานที รีโมทคอนโทรลหรือไม ชัด เครื อง ปรับอากาศภายในไม ตอบสนอง ต อสัญญาณของรีโมทคอนโทรล แบตเตอรี หมดหรือไม หน า 3 ใส แบตเตอรี ถูกขั วหรือไม หน า 3 มีการกดปุ มรีโมทคอนโทรลของเครื องใช ไฟฟ า ชนิดอื นหรือไม อากาศไม เย น เครื องปรับอากาศทำความเย น ไม เพียงพอ อุณหภูมิที ตั งไว เหม...

Страница 17: ...เครื อง 2 กดปุ ม เพื อหยุดการทำงาน 3 สับเบรกเกอร ลง และ หรือถอดปลั กไฟออก 4 ถอดแบตเตอรี ทั งหมดออกจากรีโมทคอนโทรล เมื อเริ มใช เครื องปรับอากาศอีกครั ง 1 ทำความสะอาดแผ นกรองอากาศ หน า 6 2 ตรวจสอบว าไม มีสิ งกีดขวางที ช องลมเข า และช องลมออกของเครื อง ภายในและภายนอกอาคาร 3 ตรวจสอบว าต อสายดินถูกต องแล ว เม อไม ได ใช เคร องปรับอากาศ เป นเวลานาน รุ น MCF SD13VD MCF D18VD MCF D24VD ขนาด สูง กว าง ลึก ...

Страница 18: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN VN79B582H01 ...

Отзывы: