3 BASIC FUNCTION
3.10 Forced stop deceleration function
67
3
Timing chart
When EM2 (Forced stop 2) is turned off, the servo motor decelerates in accordance with the value of [Pr. PC24 Deceleration
time constant at forced stop]. Once the servo motor speed is below [Pr. PC07 Zero speed] after completion of the deceleration
command, the base circuit is shut off and the dynamic brake activates.
ON
OFF
ON
OFF
0 r/min
[Pr. PC24]
ON
OFF
EM2 (Forced stop 2)
(Enabled)
Dynamic brake
+
electromagnetic brake
Normal
operation
Forced stop
deceleration
Rated speed
Servo motor speed
Command
Zero speed ([Pr. PC07])
Deceleration time
Base circuit
(Energy supply to the
servo motor)
(Enabled)
(Electromagnetic brake
interlock)
MBR