42
3 BASIC FUNCTION
3.1 Outline of servo parameter and object dictionary
3
BASIC FUNCTION
This section explains each function that is used for basic operation of the servo amplifier. Set each function as required. For
advanced operation of the servo amplifier, refer to the following.
Precautions
• To prevent a malfunction and machine damage, on the first operation after setting, check the operating condition with a low
speed command.
3.1
Outline of servo parameter and object dictionary
On MR-JET servo amplifiers, the functions of the servo amplifiers are set with servo parameters, and objects enable
communication of data such as command values and feedback values with controllers.
Servo parameter
For the servo parameters that updates data periodically in the cyclic communication, do not write a value with
the engineering tool or other tools, as the values will be overwritten from the controller.
Each function of the servo amplifiers can be set with the servo parameters. The servo parameters are stored in the non-
volatile memory in the servo amplifier, are set to the initial value when shipped from the factory. Change the setting with
engineering tools or others as necessary.
The servo parameters related to the basic functions explained in this manual are shown in the following example.
When the servo parameter name is "Travel direction selection" and No. is "PA14"
[Pr. PA14 Travel direction selection]
In addition, the servo parameters in which the symbols are preceded by * are enabled by the following conditions.
• *: After setting, cycle the power, or reset the controller.
• **: After setting, cycle the power.
For a servo parameter which uses one particular digit to select a function, the position of its digit indicates the detail number of
the servo parameter, and the value in hexadecimal which is set to the digit indicates the selected function.
For example, the detail number of the servo parameter in the last digit is expressed as [Pr. PA01.0]. In addition, when a servo
parameter is set with a combination of multiple digits, the servo parameter is shown with "-" as in [Pr. PA01.0-1].
The following is an example of the servo parameter number PA01 with the setting values of "FEDCBA98" in hexadecimal.
• When setting a servo parameter with one particular digit
Servo parameter
Symbol
Name
Outline
PA14
*POL
Travel direction selection
The rotation direction of the servo motor can be set.
Initial value: 0 (CCW)
[Pr. PA01] =
PA01.0 = "8"
PA01.1 = "9"
PA01.2 = "A"
PA01.3 = "B"
PA01.4 = "C"
PA01.5 = "D"
C
D
B
F
A
E
8
9
PA01.6 = "E"
PA01.7 = "F"