14
2 CONTROL MODE
2.1 Control mode
Controlword/Statusword
By changing [Controlword (Obj. 6040h)], control commands can be given to the servo amplifier. The control status can also be
checked with [Statusword (Obj. 6041h)].
Some bits of [Controlword (Obj. 6040h)] and [Statusword (Obj. 6041h)] vary depending on the control mode. The bits that vary
depending on the control mode are listed in the following tables.
■
Controlword OMS Bit (csv)
■
Statusword OMS Bit (csv)
60A9h
VAR
SI unit velocity
U32
rw
SI unit velocity
The SI unit velocity is returned.
FEB44700h (0.01 r/min)
00000300h (pulse/s)
60B1h
VAR
Velocity offset
I32
rw
0
Velocity offset (vel units)
60B2h
VAR
Torque offset
I16
rw
0
Torque offset
Unit: 0.1 % (with rated torque being 100 %)
Bit
Symbol
Description
4
(reserved)
The value at reading is undefined. Set "0" when writing.
5
(reserved)
6
(reserved)
8
(reserved)
9
(reserved)
Bit
Symbol
Description
10
(reserved)
The value at reading is undefined.
12
Target velocity ignored
0: [Target velocity (Obj. 60FFh)] is being discarded.
1: [Target velocity (Obj. 60FFh)] is being used as a speed control loop input.
13
(reserved)
The value at reading is undefined.
Index
Sub
Object
Name
Data Type
Access Default
Description