2 INSTALLATION
2.7 Installing the mounting attachment
Selection of attachment for power regeneration converter units
Mounting attachment installation procedure
The following shows how to install the mounting attachment to the power regeneration converter unit and then to the cabinet.
It is also possible to install the mounting attachment to the cabinet first and then to the converter unit.
At the removal, it is possible to remove both the mounting attachment and the converter unit or the converter unit alone.
1.
Attach the mounting attachment to the power regeneration converter unit.
• MR-CV11K4/MR-CV18K4
• MR-CV30K4/MR-CV37K4/MR-CV45K4/MR-CV55K4/MR-CV75K4
MR-ADCACN090
Power regeneration converter unit
Mounting screw (2)
Screw size: M5
Tightening torque: 3.24 [N•m]
MR-ADCACN150
MR-ADCACN300
Power regeneration converter unit
Mounting screw (4)
Screw size: M5
Tightening torque: 3.24 [N•m]