2-34
(2) Secondary replacement (when replacing the servo motor after replacing the servo amplifier)
/Package replacement (when replacing the servo amplifier and the servo motor simultaneously)
検出器
MR- J2S
用
(MR -J4- A)
(SC-J2SJ4KT K)
I/ F
用 電源
(DC24V
)
制 御 信号 変換 ケーブル
モ ニ タ変 換 ケーブル
AC100V
単相
(注
3
)
②
①
③
④
⑤
⑥
⑦
(注
1
)
(注
4
)
∞
∞
24 V DC
⑩
⑧
⑨
⑪
CN1B
CN1A
CN3
CN 2
DC24V
電 源 接続
ケ ーブ ル
Cooling fan
Renewal kit
Servo motor
for MR-J2S
Encoder
conversion cable
Control
signal
Analog
monitor
Control signal conversion cable
Monitor conversioncable
Encoder
Power supply conversion
cable on the motor side
Encoder conversion
cable on the motor side
Brake conversion cable
on the motor side
3-phase
200 V AC to
1-phase
100 V AC
(Note3)
Power supply for I/F
(24 V DC)
Power supply for
the cooling fan
Conversioncableforthecooling
fanonthemotorside
Servo amplifier
24 V DC power supply
connection
cable
(Note6)
Regenerative
option
(Note4)
(Note2)
(Note1)
(Note5)
230 V AC
Note 1. Make sure to connect between P3 and P4. When using the power factor improving DC reactor, remove the short circuit bar
between P3 and P4 before connection.
For details, refer to MR-J4-_A Series Servo Amplifier Technical Reference Material issued by Mitsubishi Electric Corporation.
2. When using the regenerative option, make sure to mount the regeneration option between P+ and C. Ensure the connection
destinations are correct. The servo amplifier may malfunction if the connection destinations are incorrect.
For details, refer to MR-J4-_A Series Servo Amplifier Technical Reference Material issued by Mitsubishi Electric Corporation.
3. Required only when the internal power supply (24 V DC) for the I/F is used in the existing MR-J2S-_A_ servo amplifier. Not
included with the renewal tool. Note that a separate 24 V DC power supply (current capacity: 80 mA or more) is required when
replacing.
When connecting the 24 V DC power supply, use the "24 V DC power supply connection cable (model: SC-J2SJ4CTPWC5M)"
included in the package.
(Electric wire colors: Red (+ side); white (- side))
4. When connecting a power regenerative converter (FR-RC-_K) and a brake unit (FR-BU2-_K), connect between P+ and N-.
Make sure to remove the built-in regenerative resistor or the regenerative option.
For details, refer to MR-J4-_A Series Servo Amplifier Technical Reference Material issued by Mitsubishi Electric Corporation.
5. Unnecessary if electromagnetic brakes are not installed.
6. Required for the HG-JR22K1M motor only. There is no cooling fan for the HG-JR11K1M or HG-JR15K1M motors. Because
the existing wiring becomes unnecessary, insulate as needed.
No.
Product name
(1)
Servo amplifier
*1,2
(2)
Servo motor
*1
(3)
Renewal kit
(4)
Encoder conversion cable
*2
(5)
Control signal conversion cable
*2
(6)
Monitor conversion cable
*2
(7)
24 V DC power supply connection
cable
*2
(8)
Power supply conversion cable on the
motor side
(9)
Encoder conversion cable on the motor
side
(10)
Brake conversion cable on the motor
side
(11)
Conversion cable for the cooling fan on
the motor side
*1: Manufactured by Mitsubishi Electric.
*2: For secondary replacement,
replacement finished through
primary replacement
2 - 34