(6) Mounting the Terminal Block
You are going to mount the terminal
block you removed in advance to the
TE1 bracket ①.
(7) Connecting the Cables to the Replacing Servo Amplifier
① Check the names of the cables that are to be housed in Renewal
Kit. Check the abbreviations and short names of the connectors
to the servo amplifier. Connect the cables and the connectors.
* In the case of terminal block TE1, connect the cables,
starting from the right side of the amplifier.
* In the case of terminal block TE2, connect the cables,
starting from the left side of the amplifier.
Use the cable tie (an accessory in the package) to
tie up and fasten the cables in Renewal Kit.
Arrangement of
the Terminals
L
1
L
2
L
3
U
V
W
TE1
Note
A schematic view seen from
the front side of the
amplifier
① Cables to be housed in Renewal Kit
Use the cable connector that comes with
the servo amplifier for wiring. For the
details of how to connect the cables, see
the technical materials on servo
amplifiers (Model MR-J4-_A(-RJ) SERVO
AMPLIFIER INSTRUCTION MANUAL) issued by
Mitsubishi Electric corpolation.
* For the connections of the built-in
regeneration resistance and the
regeneration option, see section
3.3.2, paragraphs (9) and (10).
Terminal block
TE1
Terminal
block TE2
When a battery is not used
(an incremental system)
When a battery is used
(absolute position detection system)
① Bracket TE1
① Bracket TE1
* When mounting the bracket, pay attention to the direction
of the terminal block.
If you try to mount it in an incorrect direction, you cannot mount
it correctly. Be careful.
3 - 16