21
2) Key Component Check Procedures
Component name
Testing procedure
Tube temperature
sensing thermistor P15
Detach the connector and measure the resistance using a multimeter
(component temperature: 10°C to 30°C).
Normal
Abnormal
Between P15 pins: 8.0k
Ω
to 20.8k
Ω
Open or shorted
Room temperature and
humidity sensor board
Detach the connector and measure the resistance using a multimeter
(component temperature: 10°C to 30°C).
Normal: 47 to 51k
Ω
(between P31 pins 3 and 4)
Abnormal: Open or shorted
Compressor
With the connector detached, measure the resistance across the terminals using a
multimeter (winding temperature: 10°C to 30°C).
Normal
Abnormal
C-R side
25
Ω
~ 27
Ω
Open or shorted
C-S side
67
Ω
~ 74
Ω
Fan motor (2)
Warm air motor
Cool air motor
•
•
Measure the resistance between terminals using a multimeter
(winding temperature: 10°C to 30°C).
Normal
Abnormal
Cool air (EVA)
Warm air (COND)
Yellow-Blue
425
Ω
~ 462
Ω
216
Ω
~ 236
Ω
Open or shorted
Black-Blue
288
Ω
~ 315
Ω
219
Ω
~ 238
Ω
Solenoid coil
Measure the resistance between terminals using a multimeter
(component temperature: 10°C to 30°C).
Normal
Abnormal
2.6k
Ω
~ 2.9k
Ω
Open or shorted
e01̲mj̲e15bx̲S1-IT.indd 21
2010/06/10 17:30:15
Содержание MJ-E15BX-S1-IT
Страница 16: ...16 7 Circuit Diagram WARM AIR DAMPER COOL AIR DAMPER LOUVRE SOLENOID VALVE WARM AIR FAN COOL AIR FAN ...
Страница 17: ...17 ...
Страница 29: ...29 ...
Страница 40: ...A B C E F D H G 40 MJ E15BX S1 IT Model Structural Disassembly Diagram Case and fan structural relationship ...
Страница 49: ...Issued in 2010 06 ...