Laundry Operation
1. HIGH
①
Control Summary
(a) Dehumidifying operates continuously regardless of the humidity.
(b) The constant compressor, cool air and warm air fans operate continuously.
Target part
Compressor
Cool air fan
Warm air fan
Solenoid valve
Louvre
Damper
Operation
ON
Rank control
Rank control
OFF
Operation
mode
Dehumidifying
position
②
Laundry operations are disabled in the following cases.
(a) When the LAUNDRY switch is pressed, it switches to LAUNDRY (NORMAL) operation.
(b) When the DEHUMIDIFYING switch is pressed, it switches to the previously set DEHUMIDIFYING operation
mode (DEHUMIDIFYING LOW, DEHUMIDIFYING HIGH or AUTO).
(c) When the SPOT AIR switch is pressed, it switches to the previously set SPOT AIR operation mode (COOL AIR
LOW, COOL AIR VARY or WARM AIR).
(d) When the DEO-DRY switch is pressed, it switches to the DEO-DRY mode operation.
2. NORMAL or HEAVY
z
NORMAL
Operating time
From operation start to 30 minutes
After 30 minutes or more
Fan temperature table
0
1
2
3
Damper
position
0
1
2
3
Damper
position
Cool
air fan
Average
humidity
70%~80%
Rank7
Rank7
Rank7
Rank5
Dehumidifying
Rank7
Rank7
Rank7
Rank5
Dehumidifying
60%~69%
Rank6
Rank7
Rank7
Rank5
Dehumidifying
Rank6
Rank7
Rank7
Rank5
Dehumidifying
30%~59%
Rank6
Rank7
Rank7
Rank5
Dehumidifying
Rank6
Rank4
Rank4
Rank5
Warm air
Warm
air fan
Average
humidity
70%~80%
Rank6
Rank6
Rank6
Rank5
Dehumidifying
Rank6
Rank6
Rank6
Rank5
Dehumidifying
60%~69%
Rank6
Rank6
Rank6
Rank5
Dehumidifying
Rank6
Rank6
Rank6
Rank5
Dehumidifying
30%~59%
Rank6
Rank6
Rank6
Rank5
Dehumidifying
Rank4
Rank4
Rank4
Rank5
Warm air
z
HEAVY
Operating time
From operation start to 30 minutes
After 30 minutes or more
Fan temperature table
0
1
2
3
Damper
position
0
1
2
3
Damper
position
Cool
air fan
Average
humidity
70%~80%
Rank7
Rank7
Rank7
Rank5
Warm air
Rank7
Rank7
Rank7
Rank5
Warm air
60%~69%
Rank6
Rank7
Rank7
Rank5
Warm air
Rank6
Rank7
Rank7
Rank5
Warm air
30%~59%
Rank6
Rank7
Rank7
Rank5
Warm air
Rank6
Rank4
Rank4
Rank5
Warm air
Warm
air fan
Average
humidity
70%~80%
Rank6
Rank6
Rank6
Rank5
Warm air
Rank6
Rank6
Rank6
Rank5
Warm air
60%~69%
Rank6
Rank6
Rank6
Rank5
Warm air
Rank6
Rank6
Rank6
Rank5
Warm air
30%~59%
Rank6
Rank6
Rank6
Rank5
Warm air
Rank4
Rank4
Rank4
Rank5
Warm air
①
Control Summary
(a) The dehumidifying time changes depending on the humidity, temperature and time.
(b) The time when the humidity changes is measured, and dehumidifying operation is automatically stopped when
the laundry is dry.
(c) Normal
Target part
Compressor
Cool air fan
Warm air fan
Solenoid valve
Louvre
Damper
Operation
ON
Rank control
Rank control
OFF
Operation
mode
Dehumidifying
→
Warm air
*The damper switches when humidity drops below 60%
(d) Heavy
Target part
Compressor
Cool air fan
Warm air fan
Solenoid valve
Louvre
Damper
Operation
ON
Rank control
Rank control
OFF
Operation
mode
Warm air
e01̲mj̲e15bx̲S1-IT.indd 7
2010/06/10 17:30:01