3. COOL AIR/VARY Operation
①
Control Summary
(a) Dehumidifying operates continuously regardless of the humidity.
(b) The constant compressor, cool air and warm air fans operate continuously.
(c) Perform cool air operation by placing the damper position in cool air mode.
(d) Control fl uctuations by changing the cool air fan rank level by time.
②
Change the cool air/warm air fan rank as follows.
③
When the room temperature is 36˚C or more, the warm air fan rank is fi xed at rank 5.
Step
Cool air fan
Warm air fan
Conditions for moving to next step
Step1
Rank1
Rank4
Operation after 5 seconds
Step2
Rank4
Rank4
Operation after 2 seconds
Step3
Rank8
Rank4
Operation after 5 seconds
④
The step switching order is as follows.
(a) Step 1
→
2
→
3
→
2
→
1 ...
⑤
COOL AIR/VARY operation is disabled in the following cases.
(a) When the LAUNDRY switch is pressed, it switches to the previously set LAUNDRY operation mode (HIGH, NORMAL or HEAVY).
(b) When the DEHUMIDIFYING switch is pressed, it switches to the previously set DEHUMIDIFYING operation
mode (DEHUMIDIFYING LOW, DEHUMIDIFYING HIGH or AUTO).
(c) When the SPOT AIR switch is pressed, it switches to WARM AIR operation.
(d) When the DEO-DRY switch is pressed, it switches to the DEO-DRY mode operation.
DEO-DRY mode operation
①
Control Summary
(a) Odors are removed by heating the clothes.
(b) The following operations are performed during clothes deodorization.
Target part
Compressor
Cool air fan
Warm air fan
Solenoid valve
Louvre
Damper
Operation
ON
Rank control
Rank control
OFF
Operation
mode
Cool Air
→
Warm air
②
Startup conditions
(a) When operation is on while DEO-DRY mode operation is selected
(b) When DEO-DRY mode operation is selected by operating the DEO-DRY switch
(c) When the DEO-DRY switch is pressed during clothes deodorization, DEO-DRY mode operation is restarted
from the following step 1.
③
Operating Contents
(a) Clothes equipment operates in order of the following steps.
- Step 1 Cool air is blown through the clothes
- Step 2 Warm air is blown through the clothes
(b) Control panel operation during the above mentioned steps
Step
Cool air
fan
Warm air
fan
Compressor
Solenoid
valve
Damper
Conditions for moving to next step
Step1
Rank4
(Room temperature
35˚C or less)
Rank4
(Room temperature
35˚C or less)
ON
OFF
Cool Air
Operates for 20 min.
Step2
Rank4
(Room temperature
35˚C or less)
Rank4
(Room temperature
35˚C or less)
ON
OFF
Warm air
After 40 minutes operation, DEO-DRY
mode operation ends
④
DEO-DRY mode operation stopping condition
(a) Ends at the above mentioned step 2
(b) When the POWER switch is off
⑤
After DEO-DRY mode operation, it is disabled in the following cases.
(a) When the LAUNDRY switch is pressed, it switches to the previously set LAUNDRY operation mode (HIGH, NORMAL or HEAVY).
(b) When the DEHUMIDIFYING switch is pressed, it switches to the previously set DEHUMIDIFYING operation
mode (DEHUMIDIFYING LOW, DEHUMIDIFYING HIGH or AUTO).
(c) When the SPOT AIR switch is pressed, it switches to the previously set SPOT AIR operation mode (COOL
AIR/LOW, COOL AIR/VARY or WARM AIR).
(d) When the DEO-DRY switch is pressed, it restarts DEO-DRY mode operation from the fi rst stage (step 1).
e01̲mj̲e15bx̲S1-IT.indd 11
2010/06/10 17:30:03
Содержание MJ-E15BX-S1-IT
Страница 16: ...16 7 Circuit Diagram WARM AIR DAMPER COOL AIR DAMPER LOUVRE SOLENOID VALVE WARM AIR FAN COOL AIR FAN ...
Страница 17: ...17 ...
Страница 29: ...29 ...
Страница 40: ...A B C E F D H G 40 MJ E15BX S1 IT Model Structural Disassembly Diagram Case and fan structural relationship ...
Страница 49: ...Issued in 2010 06 ...