66
6 SYSTEM CONSTRUCTION
6.4 Connection of an External Light Cable
6.4
Connection of an External Light Cable
This section shows the procedure for connecting an external light cable.
Operating procedure
1.
Remove the protective cap from the LIGHT connector (if present).
2.
Connect the M12 connector of an external light to the LIGHT connector of the vision sensor.
3.
Connect the other end of the light cable to an external lighting device (for example, a strobe light).
Precautions
The cable is designed to connect with its key aligned with the keyway of the connector on the Vision Sensor.
Do not force the connections or damage may occur.
6.5
Connection of an Ethernet Cable
This section shows the procedure for connecting an Ethernet cable.
Operating procedure
1.
Connect the Ethernet cable's M12 connector to the vision sensor's Ethernet connector.
2.
Connect the Ethernet cable’s RJ-45 connector to the switching hub or personal computer, as applicable.
Precautions
• The cable is designed to connect with its key aligned with the keyway of the connector on the Vision Sensor.
Do not force the connections or damage may occur.
• The Ethernet cable shield must be grounded at the far end.
Whatever this cable is plugged into (usually a switching hub) should have a grounded Ethernet connector.
A digital voltmeter should be used to validate the grounding.
Содержание MELSENSOR VS70 Series
Страница 2: ......
Страница 14: ...12 1 PRODUCT OVERVIEW MEMO ...
Страница 16: ...14 2 PART NAMES MEMO ...
Страница 96: ...94 7 INSTALLATION 7 2 Registration of a Profile MEMO ...
Страница 98: ...96 8 MAINTENANCE AND INSPECTION 8 2 Clean an Image Sensor Window MEMO ...
Страница 100: ...98 9 TROUBLESHOOTING MEMO ...
Страница 111: ......