3 SPECIFICATIONS
3.1 General Specifications
15
3
3
SPECIFICATIONS
This chapter shows the specifications of vision sensor VS70s.
3.1
General Specifications
The following shows the general specifications of vision sensor VS70s.
*1 Case temperature can be confirmed using EV GetSystemConfig ("Internal.Temperature") Extended Native Mode command.
When the command is issued, it will return the internal temperature of a vision sensor in degrees Celsius.
The returned temperature will be
±
5 degrees of the case temperature of a vision sensor.
For details on the command, refer to the help of In-Sight Explorer.
*2 Additional cooling measures are required if the case temperature exceeds 50
.
Examples of such measures include:
⋅
Attach an extra heat sink to a vision sensor using M3 screws.
⋅
Lower the ambient temperature so that air can pass through a vision sensor.
*3 A vision sensor should be used in the environment where the temperature around the vision sensor is about 0 to 40
because the case
temperature is easily influenced by the environment the vision sensor is installed in.
*4 Do not install vision sensors in the following environments:
⋅
Where the ambient temperature or humidity exceed the applicable ranges
⋅
Where condensation occurs due to sudden temperature changes
⋅
Where there is corrosive or flammable gas
⋅
Where there are a lot of conductible dust, iron filings, or salt
⋅
Where in danger of organic solvents, such as benzene, thinner, and alcohol or strong alkaline substances such as caustic soda to
adhere
⋅
Where subject to much vibration or shock
⋅
Where in danger of liquid such as water, oil, or chemicals to adhere
Item
Specifications
Case temperature
0 to 50
Ambient storage temperature
-20 to 80
Maximum humidity
Less than 80% RH, no condensation
Vibration resistance
IEC 60068-2-6: A vibration of 10 G (10 to 500 Hz at 100 m/
with 15 mm width) was applied to each X, Y, and Z
direction for 2 hours.
(with cables/cable plugs and appropriate lens cover attached)
Shock resistance
IEC 60068-2-27: 18 half sinusoidal shocks (3 shocks for each X, Y, and Z direction) with 80 G (800 m/
at 11 ms)
were applied.
(with cables/cable plugs and appropriate lens cover attached)
Operating atmosphere
There is no danger of corrosive or flammable gas and strong alkaline substances to adhere.
Protective structure
IP67 (with cables connected and appropriate lens attached)
Installation location
Outside of a control panel
Содержание MELSENSOR VS70 Series
Страница 2: ......
Страница 14: ...12 1 PRODUCT OVERVIEW MEMO ...
Страница 16: ...14 2 PART NAMES MEMO ...
Страница 96: ...94 7 INSTALLATION 7 2 Registration of a Profile MEMO ...
Страница 98: ...96 8 MAINTENANCE AND INSPECTION 8 2 Clean an Image Sensor Window MEMO ...
Страница 100: ...98 9 TROUBLESHOOTING MEMO ...
Страница 111: ......