56
6 SYSTEM CONSTRUCTION
6.3 Attachment of a Lens and Light
Attachment of a C-mount lens and a lens cover accessory
Attach a C-mount lens and a lens cover accessory by following the procedure below.
Operating procedure
1.
Remove the rubber faceplate covering the image sensor window.
2.
Remove the protective film covering the threaded lens opening (if present).
3.
Place a lens cover adapter on the faceplate of the vision sensor, and insert four adapter screws and tighten.
The maximum tightening torque is 0.26 N
⋅
m.
4.
Thread a lens into the vision sensor.