6
2 FUNCTION DESCRIPTION
2.1 Program
2
FUNCTION DESCRIPTION
2.1
Program
This FB library includes the sample programs which can be used in the configuration described in "Page 3 System
Each FB operation can be checked with the sample programs.
Program configuration
List of programs
FB/FUN
Structure
Global label
Servo amplifier MR-JE-C parameter
Set the following parameters to the servo amplifier in advance.
This sample program is designed not to use the input signals of the servo amplifier. Configure the settings according to safety
measures required for system operation.
File name
Description
Model
Engineering environment
MotionControl_JEC_FBs_Q.gxw
FBD, ST program
QnUDVCPU
MELSOFT GX Works2
Program name
Description
Execution type
Description method
Sample/PrgAxis1
Each FB execution program axis 1
Scan
FBD
Sample/PrgAxis2
Each FB execution program axis 2
Scan
FBD
FB name
Description
Execution type
Description method
CCIEFBasicStart
Start of cyclic communication of the
specified axis
Scan
FBD
Program name
Description
stRemoteRegBasic
Device definition of the refresh setting used in the FB library
Label name
Description
G_stLinkBasic
Refresh data information used in the FB library
Axis1
Axis 1 information
Axis2
Axis 2 information
Parameter
Setting detail
Axis 1
Axis 2
PA01: Operation mode
Profile mode
1009
1009
PD01: I/O signal automatic on
selection 1
Forced stop (automatic on)
Forward rotation stroke end
(automatic on)
Reverse rotation stroke end
(automatic on)
1C00
1C00
Содержание MELSEC-Q-MR-JE-C
Страница 1: ...PLCopen Motion Control Function Block Reference MR JE C ...
Страница 2: ......
Страница 4: ...2 INSTRUCTION INDEX 63 REVISIONS 65 TRADEMARKS 66 ...
Страница 7: ...1 OVERVIEW 1 5 Notes 5 1 MEMO ...
Страница 64: ...62 3 FB LIBRARY 3 5 Troubleshooting MEMO ...
Страница 66: ...64 MEMO ...