3 FB LIBRARY
3.2 Details of the FB Library
Function overview
Item
Description
Applicable hardware and
software
Applicable CPU
QnUDVCPU
Applicable engineering tool
GX Works2
Language
Structured Text
Number of basic steps
228 steps
Function description
This FB clears an error (alarm) of the specified axis.
The FB is executed when Execute turns ON, and Busy turns ON when the processing is started.
Done turns ON when the error of the axis is cleared.
If Execute is turned ON while the error cause of the axis still remains, the error is not cleared. In this case, Busy remains
ON.
Turn OFF Execute once and turn ON it after clearing the error cause.
When an error has occurred in the FB, this FB turns ON Error and stores an error code in ErrorID.
For details of error codes, refer to
Restrictions and precautions
For how to eliminate error causes, refer to the instruction manual of the servo amplifier in use.
FB operation type
Pulsed execution (multiple scan execution type)
Timing chart
[Normal completion]
[Error completion]
Execute
Busy
Done
Error
ErrorID
0
Execute
Busy
Done
Error
ErrorID
Error code
Содержание MELSEC-Q-MR-JE-C