![Mitsubishi Electric MELSEC-Q-MR-JE-C Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/mitsubishi-electric/melsec-q-mr-je-c/melsec-q-mr-je-c_reference-manual_239167025.webp)
3 FB LIBRARY
3.2 Details of the FB Library
23
3
3.2
Details of the FB Library
MC_Power (Operation Possible)
Name
MC_Power_JEC
Overview
Labels
■
I/O label
■
Input labels (Load:
П
: Always,
: Only at start)
■
Output labels
Item
Description
Function overview
Switches the status of the servo amplifier of the specified axis to Operable.
Symbol
[Structured Ladder]
Symbol
[Structured Text]
MC_Power_JEC (Axis, Enable, Status, Error, ErrorID)
No.
Variable name
Name
Data type
Setting range
Description
(1)
Axis
Axis information
AXIS_REF_JEC
Page 59 AXIS_REF_JEC (Axis information)
No.
Variable name
Name
Data type
Import
Setting
range
Description
(2)
Enable
Enable
Bit
ON, OFF
While Enable is ON, the axis control is valid.
No.
Variable name
Name
Data type
Default value
Description
(3)
Status
Operable
Bit
OFF
It indicates that the servo amplifier is ready for
operation.
(4)
Error
Error
Bit
OFF
When ON, it indicates that an error has occurred in
the FB.
(5)
ErrorID
Error code
Word [unsigned]
0
The error code generated in the FB is returned.
DUT: Axis
Axis :DUT
B: Enable
Status :B
Error :B
ErrorID :UW
MC_Power_JEC
(2)
(5)
(4)
(3)
(1)
(1)
Содержание MELSEC-Q-MR-JE-C
Страница 1: ...PLCopen Motion Control Function Block Reference MR JE C ...
Страница 2: ......
Страница 4: ...2 INSTRUCTION INDEX 63 REVISIONS 65 TRADEMARKS 66 ...
Страница 7: ...1 OVERVIEW 1 5 Notes 5 1 MEMO ...
Страница 64: ...62 3 FB LIBRARY 3 5 Troubleshooting MEMO ...
Страница 66: ...64 MEMO ...
Страница 69: ......