18
─
Type
Pulse input setting
“oFF”
SW2-2: OFF
Charged 12 V DC/24 V DC
Operation signal: 12 V DC/24 V DC
Stop signal
: 0 V
Uncharged a-contact
(Current drawn: 10 mA or greater)
Operation signal: Close
Stop signal
: Open
Level signal
Pulse input setting
“on”
SW2-2: ON
Charged
12 V DC/24 V DC
Uncharged a-contact
Start/stop is inverted with each
pulse
Pulse signal
PZ-60DR-E
(Lossnay remote
controller) can-
not be used.
SW2-2: OFF
• Connect the signal cable of Mr. Slim to Lossnay, and per-
form the Lossnay interlock settings from the A-control
remote controller or the K-control remote controller.
• The system is started/stopped by interlocking with Start/
Stop of the A-control remote controller or K-control remote
controller.
• The system is started/stopped by interlocking with the venti-
lation setting of the A-control remote controller.
• The Mr. Slim operation mode, target temperature, and other
internal information can also be brought in.
Systems
interlocked
with Mr.
Slim
Pulse input setting
“oFF”
SW2-2: OFF
• City Multi indoor units and Lossnay are connected by
M-NET, and the Lossnay interlock setting is performed from
the remote controller or system controller.
• The system is started/stopped by interlocking with Start/
Stop of the MA remote controller or ME remote controller
and the ventilation setting.
• The City Multi indoor unit operation mode, target tempera-
ture, and other internal information can also be brought in.
Systems
interlocked
with
Mitsubishi
City Multi
indoor units
(5) Interlocking with external devices
Input signal
The system will interlock with the following input signals from external devices and start/stop.
systems having multiple Lossnay units, input the signal to the “Main” Lossnay.
Multiple units
PZ-60DR-E
(Remote controller
function selection)
PZ-60DR-E Not Used
(Function selec-
tion switch)
Signal, and operation
Setting Method
Pulse width 200 ms or greater
Ventilation mode change recommendation (RECOMMENDED, VENTILATION MODE) display
When PZ-60DR-E is used and the ventilation mode is set to Lossnay ventilation or bypass ventilation,
“RECOMMENDED” and “VENTILATION MODE” may be displayed alternately (for 10 minutes maximum).
This function informs the user of the suitable ventilation mode according to the automatic ventilation algo-
rithm. When a ventilation mode change recommendation has been displayed, more comfortable ventilation
can be provided by pressing the “Function selector” button of the remote controller and switching to another
ventilation mode.
( We r ecommend that “AUTO” be selected for the ventilation mode; however, there is no problem in leaving
the ventilation mode unchanged with “RECOMMENDED” “VENTILATION MODE” displayed.)