15
─
Fixed to automatic ventilation.
Stand-alone/multi-
ple Lossnay and
Lossnay remote
controller:
PZ-41SLB-E
Basic System
M- NET
Control
Fixed to automatic ventilation.
Lossnay remote controller
PZ-60DR-E
The “Function selector” button of the remote control-
ler permits ventilation mode switching for automatic ,
Lossnay, and bypass ventilation. Bypass ventilation is
set at the time of night purge operation, and ventilation
mode switching is not possible.
Stand-alone/mul-
tiple Lossnay
and Lossnay
remote controller:
PZ-60DR-E
Lossnay remote controller
PZ-52SF-E
The “Function selector” button of the remote control-
ler permits ventilation mode switching for automatic ,
Lossnay, and bypass ventilation.
Stand-alone/mul-
tiple Lossnay
and Lossnay
remote controller:
PZ-52SF-E
M-NET controller
The “Operation mode” button of the system remote con-
troller and the centralized controller permits ventilation
mode switching for automatic , Lossnay, and bypass
ventilation.
( The schedule timer, ON/OFF remote controller, and the
group remote controller do not permit ventilation mode
selection.)
M-NET
Lossnay central
control system
ME remote controller
PAR-F27MEA,
MA remote controller
PAR-20/21MAA
M-NET
System interlocked
with City Multi
indoor units
Up to two of the Lossnay remote controllers PZ-60DR-E, PZ-41SLB-E, and PZ-52SF-E
can be used in the same group, but they cannot be used together with a different remote
controller. When using two remote controllers, be sure to use the same model of the re-
mote controller.
PZ-41SLB-E cannot be used in M-NET control. When controlling Lossnay in M-NET con-
trol, use PZ-60DR-E or PZ-52SF-E.
Caution
System
Lossnay remote controller
PZ-60DR-E
The “Function selector” button of the remote control-
ler permits ventilation mode switching for automatic,
Lossnay, and bypass ventilation. Bypass ventilation is
set at the time of night purge operation, and ventilation
mode switching is not possible.
Stand-alone/multi-
ple Lossnay and
Lossnay remote
controller:
PZ-60DR-E
Lossnay remote controller
PZ-41SLB-E
The “Function selector” button of the remote control-
ler permits ventilation mode switching for automatic,
Lossnay, and bypass ventilation.
A-control remote controller
K-control remote controller
( Remote controller connection
prohibited with Lossnay )
Fixed to automatic ventilation.
System interlocked
with Mr. Slim
None
Level signal/pulse
signal output
device and external
device only
Remote controllers
System controllers
Ventilation mode
Damper control for each system
The control indicated below can be performed according to the system that is paired