background image

6

1

2

Do not install when the product (power cable) is 
electrifi ed. 

Doing so may result in electric shocks.

Use single

-

phase 220

-

240V power.

Using the incorrect power supply may cause fi res, 
electric shocks or malfunctions.

Power cable

230
207
164
57.5

Appr

ox. 500mm

267

68

635

Conduit box

Recommended 
installation heights
For men: 925mm
For women: 905mm

Power cable hole (rear face) 

Terminal block 

Appliance external shape 

79.5 103.5

Unit (mm)

10

15.5

R3.5

R3.5

7

7

Detailed view of 
installation holes

230
207
164
57.5

Mounting screws 
(Included)

Installation 
panel 

635

Recommended 
installation heights
For men: 925mm
For women: 905mm

Appliance shape

79.5 103.5

Appliance mounting 
screw position 

Unit (mm)

Installation method 

Check

Single

-

phase 220

-

240V power is being used. 

Make sure that a ground

-

fault circuit interrupter is installed in the fixed wiring.

 A single wire (cable core: between 2.0mm

2

 and 3.0mm

2

) is being used for the power cable.

Make sure that a means for 
disconnection is incorporated in the fixed 
wiring in accordance with the wiring rules.

Fix the installation panel to the wall using 
the 4 mounting screws.

The position illustrated on the right is 

recommended. 

Use commercially available screw anchors when 

installing the appliance on a concrete wall.

Reinforce any walls made with materials other 

than concrete before installation. 

Leave a space of at least 130mm below 
the appliance. 
Dirt or water sucked into the appliance 
may damage it.

Follow the illustration on the right for the internal 
wiring.

50

6.5

15

Appliance mounting screw 
position 

Cautions

15

6.5

50

Caution

Warning

 

Содержание JT-SB216JSH2-H-NE

Страница 1: ...horoughly before beginning installation to ensure the appliance is installed safely and correctly Local installation standards should be obeyed and installation should be performed by the dealer or a qualified professional 1509876HC2301 GB INDEX Safety Precautions 2 Pre installation checks 3 Checking the installation environment 3 Checking the appliance accessories and items required for installati...

Страница 2: ...andards Incorrect wiring can cause electric shocks and fires Use single phase 220 240V power Using the incorrect power supply may cause fires electric shocks or malfunctions Use exclusive wiring Using this appliance with other devices on a branch socket may cause abnormal heat which may cause fires Be sure to install a ground fault circuit interrupter Not doing so may result in electric shocks A mean...

Страница 3: ... with water Where there is a risk of water splashing Locations where the appliance is direct sunlight or strong light May cause the sensor to malfunction Rooms that have a sterilization basin swimming pools bathrooms Check the appliance accessories and items required for installation Main unit Longer than 150mm Prepare if required Single wire for internal wiring Cable core between 2 0mm2 and 3 0mm...

Страница 4: ...ir filter air intake Maximum width of main unit 219 2 93 189 Display Heater type JSH2 Power lamp Heater lamp Check lamp Terminal block Power cable hole Clip hole Names of parts and external dimensions Front Rear Unit mm Front panel Front panel mounting screws 263 267 77 68 79 5 103 5 300 Heater less type KSN2 ...

Страница 5: ...least 150mm on both sides of the appliance to allow for maintenance Suitable walls Flat walls with no unevenness Walls that can support the weight of the appliance Reinforce any walls made with materials other than concrete When installing on a concrete wall use commercially available metal screw anchors Making the appliance easier to use Refer to the Installation position guide Leave 200mm recomm...

Страница 6: ...m Installation method Check Single phase 220 240V power is being used Make sure that a ground fault circuit interrupter is installed in the fixed wiring A single wire cable core between 2 0mm2 and 3 0mm2 is being used for the power cable Make sure that a means for disconnection is incorporated in the fixed wiring in accordance with the wiring rules Fix the installation panel to the wall using the 4 ...

Страница 7: ...emove the drain tank and air filter 2 Remove the front panel mounting screws 2 and remove the front panel 3 Remove the terminal cover mounting screw 1 and remove the terminal cover Be careful not to lose the rubber bushing Front panel 4 Hole Power cable Power cable Run the power cable through the hole in the back of the appliance and pull it through the appliance ...

Страница 8: ...o the terminal block No polarity 3 Check that the power cable is securely fixed to the terminal block 4 Clip and screw the power cable into the position shown on the right Use single phase 220 240V power Using the incorrect power supply may cause fires electric shocks or malfunctions Terminal block Warning 1 Remove 12mm single wire or 8mm stranded wire of wire sheath from the end 70 12 65 8 Insulate...

Страница 9: ... details of where to insert the plugs Use a screwdriver that is longer than 150mm 2 Check that the power cable is not trapped behind the main unit Adjust the length of the power cable in the switch box so that the power cable does not become trapped 3 Gently press the appliance onto the wall and fix it in place using mounting screws 2 Cautions If you are using commercially available φ 4 screws use ...

Страница 10: ...TANDARD settings with the customer beforehand The user cannot adjust the settings after installation is complete The JT SB216KSN2 W NE does not have a heater switch Cautions Do not install when the product power cord is electrified Doing so may result in electric shocks 1 Change the settings 1 Engage the groove of the front panel on the appliance 2 Reattach the front panel with the front panel moun...

Страница 11: ...even if the heater switch is turned on As the heater is a simple heater if the room temperature is less than 18ºC the air may feel cold Is the heater lamp in the display on 5 Is the appliance mounted securely without any vibration or abnormal noises Do not turn the ground fault circuit interrupter on while hands or other objects are inside the hand drying area If the display lamp flashes turn the g...

Страница 12: ...r durée de service doivent être éliminés séparément des ordures ménagères Si un symbole chimique est imprimé sous le symbole illustré ci dessus il signifie que la batterie ou l accumulateur contient une certaine concentration de métal lourd Elle sera indiquée comme suit Hg mercure 0 0005 Cd cadmium 0 002 Pb plomb 0 004 Dans l Union Européenne il existe des systèmes sélectifs de collecte pour les p...

Страница 13: ...n Hjelp oss å bevare det miljøet vi lever i Suomi Tämä MITSUBISHI ELECTRIC tuote on suunniteltu ja valmistettu korkealuokkaisista materiaaleista ja tai osista jotka voidaan kierrättää ja käyttää uudelleen Tämä symboli tarkoittaa että sähkö ja elektroniikkalaitteet paristot ja akut täytyy niiden käyttöiän jälkeen hävittää erillään talousjätteistä Jos yllä olevan symbolin alapuolelle on painettu kem...

Страница 14: ... Mitsubishi Electric Europe B V 1 George Street Harman House Uxbridge Middlesex UB81QQ Commercial registration no 33279602 0 66 0 05 6680 20600 1 0 Your product should be disposed of separately from household waste in line with local laws and regulations When this product reaches its end of life dispose of it at your local waste collection point recycling centre The separate collection and recycli...

Страница 15: ...rror Microcomputer error Fuse fusion Insertion of foreign objects continuous operation Overvoltage impress undervoltage impress control circuit Power circuit blower Air filter blower power circuit Blower short circuit power circuit overcurrent Power circuit disconnected motor Power circuit disconnected motor Control circuit Current fuse thermal fuse in motor Power LED Heater LED Check LED Heater L...