8
−
Power
cable
Terminal
block
5
Power cable hole
Power cable
Mounting
screw
Cord clip
(Included)
Cord clip mounting screw hole
2. Screw the power cable to the terminal block.
Proper torque is 1.2N·m(11 lbf·in)
Screw
Power cable
Installation (Continued)
Wire it to the terminal block. (No polarity)
3. Check that the power cable is securely fi xed
to the terminal block.
4. Clip and screw the power cable into the
position shown on the right.
Use single-phase 220-240V power.
Using the incorrect power supply may cause fi res, electric shocks or
malfunctions.
Terminal
block
Warning
1. Remove 12mm (single wire) or 8mm
(stranded wire) of wire sheath from the
end.
70
12
65
8
Insulated ring
tongue terminal
■
Single wire
■
Stranded wire
Unit (mm)