When installing

Do not install in the following types of location, as this may cause malfunction.

Locations where the temperature could be lower than  0˚C or higher than 40˚C.
Locations where the humidity could be lower than 5%RH or higher than 95%RH.
Locations where the unit may come into direct contact with water.
Locations where the unit is under direct or strong sunlight. (May cause sensor to malfunction.)
Locations where there is a lot of condensation.
Locations where corrosive, neutral, or reductive gases are present.

Locations where salt damage may occur.

Vehicles (incl. vessels, trains.)

Installation location





Install the unit somewhere easy to use, as shown below.
If the unit is installed too low, water may get on it when the floor is being cleaned.
If water gets inside, it may damage the unit or moisten the sound-absorbent material, leading to bacterial growth.

The left side of the unit must be at least 150 mm away from any walls, as that is where the power switch is located.

Ensure there are no mirrors or walls near the right side, as drops of water may splash when drying hands.
 (We recommend a distance of at least 100 mm.)

Avoid locations where people or doors might bump into the unit.

Choose a completely flat surface on the wall to install the unit.

If the wall is not concrete, reinforce it before installation.

Avoid to install the unit any place where foods, tableware, or the likes are handled nearby because water may 
splash.

Do not embed the unit in the wall.

Make sure to secure distances larger than those listed below away from walls of building, etc.

Location

Clearance

Top

Left

Right

Front

Rear

Bottom

Open

150mm

100mm

Open

140mm

Rear face

hand dryer

Right face

Bottom face

Left face

100

150

140

Unit (mm)

Power controll section

Drain tank

Front panel

Unit

Installation panel screw

Installation panel

Check lamp

Heater lamp

Heater switch

Power lamp

Display

Front panel 

mounting screws

Power switch

Air speed
knob

Recommended installation heights:
Men: 940 mm 
Women: 920 mm

3

-

+

OFF

ON

OFF

ON

Power

Air sp

eed

Heater

JT-SB116EH-W-CA-IM_874HD7001-GB    06.12.9  2:13  PM    ページ 8

Содержание JT-SB116EH-W-CA

Страница 1: ...Young children should be supervised to ensure that they do not play with the appliance Do not modify or disassemble more than necessary This may cause fire electric shock or injury Do not install in shower room or other locations with a great deal of humidity in the air where condensation may form on the unit or where the unit may come in direct contact with water This may cause electric shock or ...

Страница 2: ...tion panel screws 5x30 self tapping 6 Installation panel 1 Clip 1 Accessories 98 169 Drain tank Heater Unit mm Air filter Power cord hole rear Terminal block Terminal block 247 835 62 152 56 322 260 300 777 222 2 106 Clip mounting screw 1 2 ...

Страница 3: ... mm away from any walls as that is where the power switch is located Ensure there are no mirrors or walls near the right side as drops of water may splash when drying hands We recommend a distance of at least 100 mm Avoid locations where people or doors might bump into the unit Choose a completely flat surface on the wall to install the unit If the wall is not concrete reinforce it before installa...

Страница 4: ...round wire If no conduit box is installed the power cord could hinder the unit from seating snugly on the wall Power cord with ground wire Approx 400mm Remove the drain tank Do not use socket outlets near water Follow local standards and guidelines Make sure that the power supply is a single phase alternating current 120V Make sure that a ground fault circuit interrupter is installed in the fixed ...

Страница 5: ...et in the screw hole 1 2 Remove screws 2 pcs Disengage the front panel at its groove from the unit Then remove the panel Run the power cord through the unit and secure to the installation panel 2 Remove the terminal cover 1 Remove the front panel Remove the terminal cover mounting screw Then pull to remove the cover toward you 3 Groove Front panel mounting screw Front panel Unit Terminal cover mou...

Страница 6: ...s install on the unit as it was Confirm that the front panel is fitted securely 1 Install the front panel 5 1 2 3 4 1 2 3 Remove the wire sheath for 15 mm from the end Connect the ground wire using the ground screw provided at the right side of the terminal block and washer Use the washer at the position as illustrated at right Screw tighten the power cord to the terminal block securely Check by p...

Страница 7: ... the power switch on Turn on power by using the means for disconnection Is the power lamp in the display on Dry hands Is the air blowing Turn the air speed knob while inserting the hands Turn on the heater switch Does the air speed change Is the heater lamp illuminating at the display Does hot air blow out It takes a few minutes before hot air blows after turning on the switch Burning smell of oil...

Страница 8: ...1 3 Komaba cho Nakatsugawa City Gifu Prefecture Japan ...

Отзывы: