Installation
2
●
●
If the wall is concrete, use commercially available
metal screw plugs (curl plugs, etc.).
If the wall is not concrete, reinforce it before
installation.
Adjust the appropriate settinng heights.
Attach the installation panel to the wall using the
6 installation screws.
204
100
50
172.5
50
50
674
50
50
50
18.5
57.5
684
50
50
50
Installation hole detail
R3.5
7
10
Installation screws
(included)
Installation panel
For a conduit box
Unit:mm
1
Install a conduit box.
Install a conduit box in the wall. Then pull the power
cord out from the conduit box with approx 400mm
(together with the ground wire).
●
If no conduit box is installed, the power cord could
hinder the unit from seating snugly on the wall.
Power cord
(with ground wire)
Approx.400mm
Remove the drain tank.
Do not use socket-outlets near water.
(Follow local standards and guidelines)
●
Make sure that the power supply is a single-phase alternating current 120V.
●
Make sure that a ground-fault circuit interrupter is installed in the fixed wiring.
●
Make sure that a means for disconnection is incorporated in the fixed wiring in accordance with the wiring rules.
●
Turn off power by using the means for disconnection.
●
Use wires in compliance with the wiring rules within a range of 1.0 mm
2
or over and less than 2.5 mm
2
.
Drain tank
Unit
Warning
Important!
Follow instructions
Men: 940 mm
Women: 920 mm
Recommended installation heights: