![background image](http://html.mh-extra.com/html/mitsubishi-electric/freqrol-cs80/freqrol-cs80_manual_1811908021.webp)
8
Para
meter
list
21
Parameter list (by parameter number)
For simple variable-speed operation of the inverter, the initial values of the parameters may be used as they are. Set the necessary
parameters to meet the load and operational specifications. Parameter setting, change, and check can be made on the operation panel.
NOTE
• The changing of the parameter settings may be restricted in some operating statuses. Use
Pr.77 Parameter write selection
to change the
setting.
Function
Pr.
Pr.
group
Name
Setting range
Minimum
setting
increment
Initial
value
Customer
setting
B
a
sic f
unct
ion
0
G000
Torque boost
0 to 30%
0.1%
1
H400
Maximum frequency
0 to 120 Hz
0.01 Hz
120 Hz
2
H401
Minimum frequency
0 to 120 Hz
0.01 Hz
0 Hz
3
G001
Base frequency
10 to 400 Hz
0.01 Hz
50 Hz
4
D301
Multi-speed setting (high speed)
0 to 400 Hz
0.01 Hz
50 Hz
5
D302
Multi-speed setting (middle speed)
0 to 400 Hz
0.01 Hz
30 Hz
6
D303
Multi-speed setting (low speed)
0 to 400 Hz
0.01 Hz
10 Hz
7
F010
Acceleration time
0 to 3600 s
0.1 s
10 s
15 s
8
F011
Deceleration time
0 to 3600 s
0.1 s
10 s
15 s
9
H000
Electronic thermal O/L relay
0 to 500 A
0.01 A
Inverter
rated
current
DC injection
bra
ke
10
G100
DC injection brake operation frequency
0 to 120 Hz
0.01 Hz
3 Hz
11
G101
DC injection brake operation time
0 to 10 s
0.1 s
0.5 s
12
G110
DC injection brake operation voltage
0 to 30%
0.1%
—
13
F102
Starting frequency
0 to 60 Hz
0.01 Hz
0.5 Hz
JO
G
op
erat
ion
15
D200
Jog frequency
0 to 400 Hz
0.01 Hz
5 Hz
16
F002
Jog acceleration/deceleration time
0 to 3600 s
0.1 s
0.5 s
—
17
T720
MRS input selection
0, 2, 4
1
0
—
18
H402
High speed maximum frequency
120 to 400 Hz
0.01 Hz
120 Hz
—
19
G002
Base frequency voltage
0 to 1000 V, 8888, 9999
0.1 V
8888
Ac
cel
e
ration/
decel
erat
ion
tim
e
s
20
F000
Acceleration/deceleration reference
frequency
1 to 400 Hz
0.01 Hz
50 Hz
S
tall
pr
event
ion
22
H500
Stall prevention operation level
0 to 200%
0.1%
150%
23
H610
Stall prevention operation level
compensation factor at double speed
0 to 200%, 9999
0.1%
9999
Mul
ti-speed
set
ting
24
to
27
D304
to
D307
Multi-speed setting (speed 4 to speed 7)
0 to 400 Hz, 9999
0.01 Hz
9999
—
29
F100
Acceleration/deceleration pattern selection
0, 2
1
0
—
30
E300
Regenerative function selection
0, 2
1
0
Frequ
ency jump
31
H420
Frequency jump 1A
0 to 400 Hz, 9999
0.01 Hz
9999
32
H421
Frequency jump 1B
0 to 400 Hz, 9999
0.01 Hz
9999
33
H422
Frequency jump 2A
0 to 400 Hz, 9999
0.01 Hz
9999
34
H423
Frequency jump 2B
0 to 400 Hz, 9999
0.01 Hz
9999
35
H424
Frequency jump 3A
0 to 400 Hz, 9999
0.01 Hz
9999
36
H425
Frequency jump 3B
0 to 400 Hz, 9999
0.01 Hz
9999
—
40
E202
RUN key rotation direction selection
0, 1
1
0
Freque
ncy
det
ect
ion
41
M441
Up-to-frequency sensitivity
0 to 100%
0.1%
10%
42
M442
Output frequency detection
0 to 400 Hz
0.01 Hz
6 Hz
43
M443
Output frequency detection for reverse
rotation
0 to 400 Hz, 9999
0.01 Hz
9999
Parameter list
Содержание FREQROL-CS80
Страница 1: ...COMPACT SMART INVERTER FREQROL CS80 FACTORY AUTOMATION ...
Страница 36: ...36 ...
Страница 37: ...37 ...