Option
a
n
d
Pe
rip
h
e
ral
Device
s
10
28
Option List
∗1
The battery (CR1216: a diameter of 12 mm, a hight of 16 mm) is not bundled.
Name
Model
Applications, Specifications, etc.
Applicable Inverter
S
tand-
alon
e S
hare
d
Liquid crystal display operation
panel
FR-LU08
Graphical operation panel with liquid crystal display
All capacities
Parameter unit (8 languages)
FR-PU07
Interactive parameter unit with LCD display
All capacities
Enclosure surface operation
panel
FR-PA07
This operation panel enables inverter operation and monitoring of
frequency, etc. from the enclosure surface
All capacities
Parameter unit connection cable
FR-CB20[]
Cable for connection of operation panel or parameter unit
[] indicates a cable length. (1m, 3m, 5m)
All capacities
Operation panel connection
connector
FR-ADP
A connector to connect the operation panel to the parameter unit
connection cable.
All capacities
DIN rail attachment
FR-UDA01, 02
Attachment for installation on DIN rail
According to capacities
(excluding inverters FR-
CS84-120 to 295).
AC reactor
FR-HAL
For harmonic current reduction and inverter input power factor
improvement
According to capacities
EMC Directive compliant noise
filter
SF
FR-E5NF
FR-S5NFSA
EMC Directive (EN61800-3 C3) compliant noise filter
According to capacities
EMC compliant EMC filter
installation attachment
FR-AAT02
For installation of the inverter to the EMC Directive compliant EMC
filter (SF).
FR-CS84-230, 295
Radio noise filter
FR-BIF(H)
For radio noise reduction (connect to the input side)
All capacities
Line noise filter
FR-BSF01
FR-BLF
For line noise reduction
All capacities
Brake unit
Resistor unit
Discharging resistor
FR-BU2
FR-BR
GZG, GRZG type
For increasing the braking capability of the inverter (for high-inertia
load or negative load)
Brake unit, electrical-discharge resistor and resistor unit are used in
combination
According to capacities
Power regeneration common
converter
Stand-alone reactor dedicated for
the FR-CV
FR-CV
FR-CVL
Unit which can return motor-generated braking energy back to the
power supply in common converter system
According to capacities
High power factor converter
FR-HC2
The high power factor converter switches the converter section on/off
to reshape an input current waveform into a sine wave, greatly
suppressing harmonics. (Used in combination with the standard
accessory.)
According to capacities
Surge voltage suppression filter
FR-ASF
Filter for suppressing surge voltage on motor
According to capacities
(three-phase 400 V
class only)
FR-BMF
According to capacities
(FR-CS84-120 to 295
only)
Ot
h
er
s
Pilot generator
QVAH-10
For tracking operation. 70V/35VAC 500Hz (at 2500r/min)
All capacities
Deviation sensor
YVGC-500W-NS
For continuous speed control operation (mechanical deviation
detection) Output 90VAC/90°
Frequency setting potentiometer
WA2W 1k
Ω
For frequency setting. Wire-wound 2W 1k
Ω
type B characteristic
Analog frequency meter
(64mm
×
60mm)
YM206NRI 1mA
Dedicated frequency meter (graduated to 130Hz). Moving-coil type DC
ammeter
Calibration resistor
RV24YN 10k
Ω
For frequency meter calibration.
Carbon film type B characteristic
FR Configurator2
(Inverter setup software)
SW1DND-FRC2-E Supports an inverter startup to maintenance.
Option and Peripheral Devices
Содержание FREQROL-CS80
Страница 1: ...COMPACT SMART INVERTER FREQROL CS80 FACTORY AUTOMATION ...
Страница 36: ...36 ...
Страница 37: ...37 ...