8
Para
meter
list
23
—
161
E200
Frequency setting / key lock operation
selection
0, 1, 10, 11
1
0
Au
to
mati
c
re
st
art
165
A710
Stall prevention operation level for restart
0 to 200%
0.1%
150%
Curren
t
det
ect
ion
167
M464
Output current detection operation selection
0, 1
1
0
—
168
E000
Parameter for manufacturer setting. Do not set.
E080
—
169
E001
E081
Cu
mulative
mon
ito
r
value clear
170
M020
Watt-hour meter clear
0, 10, 9999
1
9999
171
M030
Operation hour meter clear
0, 9999
1
9999
Input
te
rminal
funct
ion
assignme
n
t
178
T700
STF terminal function selection
0 to 5, 7, 8, 10, 14, 24, 25,
37, 60, 62, 9999
1
60
179
T701
STR terminal function selection
0 to 5, 7, 8, 10, 14, 24, 25,
37, 61, 62, 9999
1
61
180
T702
RL terminal function selection
0 to 5, 7, 8, 10, 14, 24, 25,
37, 62, 9999
1
0
181
T703
RM terminal function selection
1
1
182
T704
RH terminal function selection
1
2
O
u
tput
t
e
rmi
nal
funct
ion
assignme
n
t
190
M400
NET Y0 terminal function selection
0, 1, 3, 4, 8, 11, 12, 14 to
16, 26, 46, 47, 64, 70, 91,
98, 99, 100, 101, 103,
104, 108, 111, 112, 114 to
116, 126, 146, 147, 164,
170, 191, 198, 199, 9999
1
0
191
M401
NET Y1 terminal function selection
1
1
192
M402
NET Y2 terminal function selection
1
3
193
M403
NET Y3 terminal function selection
1
9999
194
M404
NET Y4 terminal function selection
1
4
195
M405
ABC terminal function selection
1
99
Multi
-spe
ed
se
tting
232 to
239
D308 to
D315
Multi-speed setting (speed 8 to speed 15)
0 to 400 Hz, 9999
0.01 Hz
9999
—
240
E601
Soft-PWM operation selection
0, 1, 10, 11
1
1
Sl
ip
co
mp
ens
ation
245
G203
Rated slip
0 to 50%, 9999
0.01%
9999
246
G204
Slip compensation time constant
0.01 to 10 s
0.01 s
0.5 s
247
G205
Constant-power range slip compensation
selection
0, 9999
1
9999
—
249
H101
Earth (ground) fault detection at start
0, 1
1
1
—
250
G106
Stop selection
0 to 100 s, 1000 to 1100 s,
8888, 9999
0.1 s
9999
—
251
H200
Output phase loss protection selection
0, 1
1
1
Powe
r
failu
re
st
op
261
A730
Power failure stop
0 to 2
1
0
—
267
T001
Terminal 4 input selection
0 to 2
1
0
—
269
E023
Parameter for manufacturer setting. Do not set.
Pas
sw
ord
296
E410
Password lock level
1 to 6, 101 to 106, 9999
1
9999
297
E411
Password lock/unlock
(0 to 5), 1000 to 9998,
9999
1
9999
RS-
485
communication
338
D010
Communication operation command source
0, 1
1
0
339
D011
Communication speed command source
0 to 2
1
0
340
D001
Communication startup mode selection
0, 1, 10
1
0
342
N001
Communication EEPROM write selection
0, 1
1
0
343
N080
Communication error count
—
1
0
—
502
N013
Stop mode selection at communication error
0 to 2
1
0
—
520
E415
Parameter for manufacturer setting. Do not set.
C
ommu
nic
ation
549
N000
Protocol selection
0, 1
1
0
551
D013
PU mode operation command source
selection
2, 4, 9999
1
9999
—
573
A680
4 mA input check selection
1 to 3, 9999
1
9999
PI
D
co
nt
ro
l
575
A621
Output interruption detection time
0 to 3600 s, 9999
0.1 s
1 s
576
A622
Output interruption detection level
0 to 400 Hz
0.01 Hz
0 Hz
577
A623
Output interruption cancel level
900 to 1100%
0.1%
1000%
Function
Pr.
Pr.
group
Name
Setting range
Minimum
setting
increment
Initial
value
Customer
setting