59
ORIENTATION CONTROL AT A MACHINE END— V500
<Inverter I/O terminals>
*1 Assign the function of the X22 signal to any of the input terminals using "input terminal function selection" (Pr.180 to
Pr. 183, Pr. 187).
Refer to the inverter manual for details of input terminal function selection.
*2 Assign the functions of the ORA signal to any of the output terminals using "output terminal function selection"
(Pr.190 to Pr. 192, Pr. 195).
Refer to the inverter manual for details of output terminal function selection.
Symbol
Terminal
Description
X22
(*1)
Orientation command input
terminal
Used to enter an orientation signal.
SD
Common terminal
Common terminal for the orientation signal.
ORA
(*2)
In-position signal output terminal
Switched low if the orientation has stopped within the in-position
zone while the start and orientation signals are input.
Open collector output. (Permissible load 24VDC, 0.1A)
SE
Open collector output common
terminal
Common terminal for the ORA and ORM open collector output
terminals. Isolated from the common terminal of the control circuit.