30
ORIENTATION CONTROL—A500(L)
(9) For orientation control, set correct values in Pr. 350 "stop position command selection" and Pr. 360 "12-
bit data selection" (external position command selection).
If the values set are incorrect, proper orientation control will not be performed.
(10) If "8888" (DC dynamic injection external selection) is set in Pr. 11 "DC injection brake operation time",
the DC injection brake is not operated unless the X13 terminal signal is switched on. For orientation
control, the DC injection brake is operated independently of the X13 signal.
(11) When orientation control is exercised, PID control is invalid.