7
RS-232C [Direct operation specifi cation] operation setting command form (3/7)
Command name
Command
Status
Note
Start copy
(Archive supported)
CP6,
**
(1)
**
(2)
**
(3)
**
(4)
**
(8)
**
(9)
≤
RC
≥
EX,
**
(5)
CP6,
**
(1)
**
(2)
**
(3)
**
(4)
**
(8)
**
(9)
,
**
(6)
**
(7)
≥
**
(1)
:Copy destination device
02:Copy 03:Archive
10:Copy according to the calculation result of the copy range
**
(2)
:Copy destination group
<For Copy>
00:SerialBus 03:DVD/CD
04:USB
memory
<For Archive>
00:SerialBus
**
(3)
:Copy source device
01:Main 03:Archive
**
(4)
:Copy source area
<For Main>
01:Normal 02:Alarm
03:Emergency
<For Archive>
00:SerialBus (Available only when the copy
destination device is set to "02:Copy" or "10:Copy
according to the calculation result of the copy range".)
**
(5)
:Error type (Refer to page 4.)
**
(6)
:Copy mode number
00:Stop 02:Execute
04:Copy
error
**
(7)
:Data error type
00:No error
10:No device
11:No media
20:No data
30:Improper range
32:Size error
99:Other errors
**
(8)
:Copy range set method
00:Specify start and end times
01:Specify start time and capacity
02:Start time of archive
**
(9)
:
<For Copy>
00:Fixed
<For Archive>
00:Archive from the start point of recording
01:Archive from the end point of previous archive
Stop copy
CP0,
**
(1)
≤
RC
≥
EX,
**
(2)
CP0,
**
(1)
,
**
(3)
≥
**
(1)
:Copy device
02:Copy 03:Archive
**
(2)
:Error type (Refer to page 4.)
**
(3)
:Copy mode number
00:Stop 02:Execute
04:Copy
error
Command code table (continued)