32
Command code table (continued)
RS-232C [Direct operation specifi cation] menu setting command form <Setup> (4/7)
*: The commands marked with asterisk (*) are not available with DX-TL304E series.
Menu
Menu item
Command
Status
Note
Output A
4-split screen
<Menu setting>
DW,
*****
(1)
*****
(2)
≤
<Inquiry for
setting information>
DR,
*****
(1)
≤
<Writing of menu information>
RC
≥
EX,
**
(3)
DW,
***
**
(1)
*****
(2)
≥
<Reading of menu information>
RC
≥
EX,
**
(3)
DR,
*****
(1)
,
*****
(2)
≥
DX-TL308E:<Split 4a>
<Split 4b>
DX-TL304E:<Split 4>
*****
(1)
:10662-10665
*****
(1)
:10666*-10669*
10662
10663
10666*
10667*
10664
10665
10668*
10669*
*****
(2)
:
00000:CH1 00001:CH2
00002:CH3
00003:CH4 00004:CH5*
00005:CH6*
00006:CH7* 00007:CH8*
65535:-
-
**
(3)
:Error type (Refer to page 4.)
Output A
9-split screen
÷
÷
<Split 9>
*****
(1)
:10678*-10686*
10678* 10679* 10680*
10681* 10682* 10683*
10684* 10685* 10686*
*****
(2)
:
00000:CH1* 00001:CH2*
00002:CH3*
00003:CH4* 00004:CH5*
00005:CH6*
00006:CH7* 00007:CH8*
65535:-
-*
**
(3)
:Error type (Refer to page 4.)
Output A
sequential
display
Single sequential
setting
÷
÷
*****
(1)
:
10758:Display order 1
10759:Display order 2
10760:Display order 3
10761:Display order 4
10762:Display order 5*
10763:Display order 6*
10764:Display order 7*
10765:Display order 8*
*****
(2)
:
00000:CH1 00001:CH2
00002:CH3
00003:CH4 00004:CH5*
00005:CH6*
00006:CH7* 00007:CH8*
65535:-
-
**
(3)
:Error type (Refer to page 4.)
Split sequential
setting
÷
÷
*****
(1)
:10774*
*****
(2)
:
00001:ab*
**
(3)
:Error type (Refer to page 4.)
Display interval
÷
÷
*****
(1)
:10778
*****
(2)
:
00001-00030 (1 second-30 seconds)
**
(3)
:Error type (Refer to page 4.)