13
RS-232C [Direct operation specifi cation] menu setting command form <Copy Menu> (2/3)
Menu
Menu item
Command
Status
Note
Set the start
point and
capacity
Start point/year
<Menu setting>
DW,
*****
(1)
*****
(2)
≤
<Inquiry for
setting information>
DR,
*****
(1)
≤
<Writing of menu information>
RC
≥
EX,
**
(3)
DW,
***
**
(1)
*****
(2)
≥
<Reading of menu information>
RC
≥
EX,
**
(3)
DR,
*****
(1)
,
*****
(2)
≥
*****
(1)
:01070
*****
(2)
:00001-00037 (year 2001-2037)
**
(3)
:Error type (Refer to page 4.)
Start point/month
÷
÷
*****
(1)
:01071
*****
(2)
:00001-00012 (January-December)
**
(3)
:Error type (Refer to page 4.)
Start point/day
÷
÷
*****
(1)
:01072
*****
(2)
:00001-00031 (1st-31st)
**
(3)
:Error type (Refer to page 4.)
Start point/hour
÷
÷
*****
(1)
:01073
*****
(2)
:00000-00023 (hour 0-23)
**
(3)
:Error type (Refer to page 4.)
Start point/
minute
÷
÷
*****
(1)
:01074
*****
(2)
:00000-00059 (minute 0-59)
**
(3)
:Error type (Refer to page 4.)
Start point/
second
÷
÷
*****
(1)
:01075
*****
(2)
:00000-00059 (second 0-59)
**
(3)
:Error type (Refer to page 4.)
Set the capacity/
Capacity (value)
÷
÷
*****
(1)
:01076
*****
(2)
:00001-00999 (1-999)
(2 MB-999 MB, 1 GB-100 GB)
**
(3)
:Error type (Refer to page 4.)
Set the capacity/
Capacity (unit)
÷
÷
*****
(1)
:01077
*****
(2)
:
00000:MB 00001:GB
**
(3)
:Error type (Refer to page 4.)
Set the capacity/
Capacity or
media full
÷
÷
*****
(1)
:01079
*****
(2)
:
00000:Capacity
00001:Media full (Available only when the copy
destination device is DVD/CD)
**
(3)
:Error type (Refer to page 4.)
Set the end
point and
capacity
End point/year
÷
÷
*****
(1)
:01090
*****
(2)
:00001-00037 (year 2001-2037)
**
(3)
:Error type (Refer to page 4.)
End point/month
÷
÷
*****
(1)
:01091
*****
(2)
:00001-00012 (January-December)
**
(3)
:Error type (Refer to page 4.)
End point/day
÷
÷
*****
(1)
:01092
*****
(2)
:00001-00031 (1st-31st)
**
(3)
:Error type (Refer to page 4.)
End point/hour
÷
÷
*****
(1)
:01093
*****
(2)
:00000-00023 (hour 0-23)
**
(3)
:Error type (Refer to page 4.)
End point/minute
÷
÷
*****
(1)
:01094
*****
(2)
:00000-00059 (minute 0-59)
**
(3)
:Error type (Refer to page 4.)
End point/
second
÷
÷
*****
(1)
:01095
*****
(2)
:00000-00059 (second 0-59)
**
(3)
:Error type (Refer to page 4.)
Set the capacity/
Value
÷
÷
*****
(1)
:01096
*****
(2)
:00001-00010 (1-10)
**
(3)
:Error type (Refer to page 4.)
Set the capacity/
Unit
÷
÷
*****
(1)
:01097
*****
(2)
:
00001:GB
**
(3)
:Error type (Refer to page 4.)
Command code table (continued)