2
This recorder can be remotely controlled from a PC connected via a RS-232C connector.
Direct connection
Use a RS-232C crossover cable (9 pin) to connect this recorder with a personal computer. The pin layout of the RS-232C
connector varies depending on the personal computer connected. Check the pin layout and use the proper crossover
cable for the personal computer used.
This recorder
PC
RS-232C crossover cable (9 pin)
* The illustration shows an example of DX-TL308E series.
RS-232C connector
RS-232C
1
6
9
5
Pin No.
Letters
Transmission Contents
Pin No.
Letters
Transmission Contents
2
RXD
Receiving Data
6
DSR
Data Set Ready
3
TXD
Transmission Data
7
RTS
Request To Send
4
DTR
Data Terminal Ready
8
CTS
Clear To Send
5
GND
Signal Ground
RS-232C cable
Use the following RS-232C crossover cable when connecting the RS-232C connector of the personal computer and that
of this recorder.
FRAME
D-sub 9 pin (this recorder)
D-sub 25 pin (Personal computer)
FG
TXD
RXD
RTS
CTS
DSR
GND
DTR
1
2
3
4
5
6
7
20
RXD
TXD
DTR
GND
DSR
RTS
CTS
2
3
4
5
6
7
8
1) When RS-232C connector of personal
computer is D-sub 25 pin
D-sub 9 pin
D-sub 9 pin
FRAME
FRAME
RXD
TXD
DTR
GND
DSR
RTS
CTS
2
3
4
5
6
7
8
RXD
TXD
DTR
GND
DSR
RTS
CTS
2
3
4
5
6
7
8
2) When RS-232C connector of personal
computer is D-sub 9 pin
Connecting to a personal computer
Disclaimer
In no event will Mitsubishi assume responsibility or liability for the following:
• Failure caused by any program created based on the command data provided by Mitsubishi, or inconvenience,
damages, or losses resulting from such failure.
• Inconvenience, damages, or losses caused by the mistake of the description in this operation manual.
Design and specifi cations are subject to change without notice.