3 Controller
Names of each part 3-66
3.2.2 Robot CPU unit
(1) CR800-R controller
Fig.3-2 : Names of each part of the robot CPU unit (CR800-R controller)
<1> <2> LED ...................................................... Indicators for the operation status and the error status of the robot CPU.
<3> Rotary switch ........................................... Provided for maintenance. Always set it as "0."
<4>Dot matrix LED.......................................... 3-digit display indicating the operation status and error information
<5> CN1 connector......................................... Connect the SSCNET III cable between the OPT1 connector on the
controller and this connector.
<6>Network connector .................................. Connector for Ethernet communication.
<7> EMG connector........................................ Unused.
<8> MPG connector........................................ Unused.
<9> RIO connector.......................................... Unused.
<10>EXT I/F ...................................................... Unused.
READY LED
ERROR LED
CPU status
OFF
ON
Power is off or a hardware error occurred.
Flashing
OFF
During initialization.
ON
OFF
Normal operation.
ON
Flashing
Moderate error occurred.
OFF
ON/flashing
Critical error occurred.